FR75-1 Teledyne Technologies Incorporated., FR75-1 Datasheet - Page 3

no-image

FR75-1

Manufacturer Part Number
FR75-1
Description
1.0a, 60 Vdc Optically Isolated Short-circuit Protected
Manufacturer
Teledyne Technologies Incorporated.
Datasheet
FR75-1 40
NOTES:
1. For input voltages greater than 6 volts, use an external resistor in
2. Unless otherwise specified: conformance testing is at room
3. With a shorted load condition, system inductance shall be limited to
4. Relay input voltage transitions should be less than 1.0 millisecond.
5. Maximum load current ratings are with the relay in free air and
6. Loads may be attached to either the positive or negative output
7. Timing is measured from the input voltage transition to the 10% or
8. Hermeticity is not a requirement.
series with the relay input. Select resistor value with the following
equation: Rext. = (Vin–6Vdc)/15mA
temperature; the input voltage is 5 Vdc or zero volts as required; the
output load is 48 Vdc, 1 amp.
50 µH.
soldered to a printed circuit board.
terminal.
90% point on the output voltage off-to-on or on-to-off transition. Rise
and fall times are measured from the 10 to 90% points on the output
voltage transition.
7
6
5
4
3
2
1
0.01
Typical @ –40°C
Typical @ +25°C
Typical @ +85°C
0.1
SPECIFICATIONS ARE SUBJECT TO CHANGE WITHOUT NOTICE
Figure 6 — FR75-1 overload trip current vs. time
OVERLOAD TRIP CURRENT VS. TIME
MUST TRIP
MUST NOT TRIP
1.0
Trip Time (sec)
10.0
100
© 2002 TELEDYNE RELAYS
FR75-1
FR75-1\072002\Q1
1000