S3D2 Omron Corporation, S3D2 Datasheet
S3D2
Available stocks
Related parts for S3D2
S3D2 Summary of contents
Page 1
... Relay 100 to 240 VAC Transistor Relay 24 VDC Transistor * Models compatible with Sensors for PNP connections are also available. These model numbers have the suffix B (e.g., S3D2-AKB) Differences from NPN Models ON Input signals OFF Maximum applied voltage Note: S3D2-AK(B)/-CK(B)/-CC(B) models with UL certification are available. ...
Page 2
... Sync mode selection AND/OR reverse • Flip-flop • AND/OR operating mode operating mode function selection selection S3D2 Single-func- tion (AND/OR Multi-function (24 VDC) operation) S3D2-AKD S3D2-CKD S3D2-CCD 24 VDC ± 10% 2.5 VA max. (excluding Sensor power supply) 24 VDC (supplied from power supply max ...
Page 3
... FG 100to240VAC OMRON Corporation MADE IN JAPAN OMRON Corporation MADE IN JAPAN (1), (2): Power supply terminals For S3D2-AKD/-CKD/-CCD Sensors, provide 24 VDC. The polarity of terminal (2) is positive, and terminal (1) is negative. For other models, supply 100 to 240 VAC. (3): FG terminal Ground with a ground resistance of 100 Ω ...
Page 4
... Note: Numbers in parentheses indicate terminal pin numbers. Contact Output Sensors • The S3D2 has a high-speed input response of 0.1 ms, which may cause contact output models (relay output, micro-switches, etc.) to receive unnecessary input from contact bounce and chattering. Example of Unconnectable Sensor Model ...
Page 5
... Changes the range for the timer setting time. • S3D2-CK/- Setting time is in range from 0 Setting time is in range from 1 to 10s. • S3D2-CC 0.1 s: Setting time is in range from 0.01 to 0.1s Setting time is in range from 0 One-shot timer ON ...
Page 6
... S3D2-BK Note: 1. The time chart above shows the operation for an S3D2-EK when the timer 1 switch is OFF and the timer 2 switch is ON. 2. Terminals (8) and (11) are short-circuited, and the current from the S3D2 to the Sensor is 18 × max. (TYP 22 mA). S3D2 ...
Page 7
... S3D2 may cause the insides of protective casing to heat up. S3D2-AKD/-CKD/-CCD • Do not connect a load min. to models for which the S3D2 power supply inputs are to be used as is for the Sensor power supply outputs. Connecting a load min. to the Sensor’s power supply outputs will cause the fuse in the case to break ...
Page 8
... Always lay the S3D2 input lines, output lines, and the power line separately. Otherwise, malfunction due to noise may occur. Output lines (OUT, 100 to 240 VAC) • The power line, through which a large current flows (e.g., to drive a motor) should be wired Provide a distance of 200 mm min. ...
Page 9
... OMRON Corporation Industrial Automation Company http://www.ia.omron.com/ Read and Understand This Catalog Warranty and Limitations of Liability Application Considerations Disclaimers In the interest of product improvement, specifications are subject to change without notice. (c)Copyright OMRON Corporation 2008 All Right Reserved. 2008.11 ...