PAD113 Thaler Corporation, PAD113 Datasheet

no-image

PAD113

Manufacturer Part Number
PAD113
Description
High Voltage Operational Amplifier
Manufacturer
Thaler Corporation
Datasheet
HIGH VOLTAGE OPERATIONAL AMPLIFIER
Innovation by
Thaler Corp 2015 N Forbes Blvd Tucson AZ 85745 USA Phone (800)827-6006 or (520)882-4000 Fax (520)770-9222 Web Site:
The PAD113 high voltage operational amplifier is
constructed with surface mount components to
provide a cost effective solution for many
industrial applications. With a footprint only 3.8
in
that
component amplifiers or rack-mount amplifiers.
User selectable external compensation tailors the
amplifier’s
requirements. Four-wire programmable current
limit is built-in. The PAD113 also features a
substrate temperature reporting output and over-
temp shutdown. The amplifier circuitry is built on
a thermally conductive but electrically insulating
substrate mounted to an integral heat sink and fan
assembly. No BeO is used in the PAD113. The
resulting module is a small, high performance
turn-key solution for many industrial applications.
2
LOW COST
HIGH VOLTAGE – 500 VOLTS
HIGH OUTPUT CURRENT –1.5A
29 WATT DISSIPATION CAPABILITY
97 WATT OUTPUT CAPABILITY
INTEGRATED HEAT SINK AND FAN
PIEZO TRANSDUCER DRIVE
HIGH VOLTAGE INSTRUMENTATION
SEMICONDUCTOR TESTING
the PAD113 offers outstanding performance
rivals
PowerAmp Design
APPLICATIONS
KEY FEATURES
DESCRIPTION
response
much
more
to
expensive
the
application
hybrid
A critical task in any power amplifier application
is cooling the amplifier. Until now component
amplifier manufacturers often treated this task as
an after-thought, left for the user to figure out. At
Power Amp Design the best heat sink and fan is
chosen at the start and becomes an integral part of
the overall amplifier design. The result is the most
compact
combination at the lowest cost. In addition, this
integrated solution concept offers an achievable
real-world power dissipation rating, not the ideal
rating usually cited when the amplifier case is
somehow kept at 25
to
components.
specify,
PAD113 INSTALLED IN EVALUATION KIT
and
A NEW CONCEPT
procure
volumetric
o
C. The user no longer needs
or
assemble
efficient
www.Thaler.com
separate
PAD113
design
Rev H

Related parts for PAD113

PAD113 Summary of contents

Page 1

... The amplifier circuitry is built on a thermally conductive but electrically insulating substrate mounted to an integral heat sink and fan assembly. No BeO is used in the PAD113. The resulting module is a small, high performance turn-key solution for many industrial applications. Thaler Corp 2015 N Forbes Blvd Tucson AZ 85745 USA Phone (800)827-6006 or (520)882-4000 Fax (520)770-9222 Web Site: ...

Page 2

... VIEW FROM COMPONENT SIDE NC -Vcc +IL -IL OUT2 - SLEW RATE GAIN Cc * SEE APPLICATION CIRCUITS 1 150pF 3V/uS FOR OTHER CONNECTIONS > 15 33pF 25V/uS AND FUNCTIONS. > 50 10pF 40V/uS CIRCUIT & CONNECTIONS FEEDBACK & LOAD C2 PAD113 www.Thaler.com 2 ...

Page 3

... PAD113 HIGH VOLTAGE OPERATIONAL AMPLIFIER __________________________________________________________________________________ SUPPLY VOLTAGE, +HV to −HV 500V SUPPLY VOLTAGE, +Vcc to −Vcc 500V SUPPLY VOLTAGE, +Vcc +HV+15V SUPPLY VOLTAGE, −Vcc −HV-15V OUTPUT CURRENT, peak 1.5A, within SOA POWER DISSIPATION, internal, DC 29W Total PARAMETER INPUT OFFSET VOLTAGE OFFSET VOLTAGE vs. temperature OFFSET VOLTAGE vs ...

Page 4

... See application note AN-16 for PCB layout guidelines. EXTERNAL CIRCUIT COMPONENTS The output of the PAD113 can swing up to +/- 240V and this may stress or destroy external components that are often not seriously considered when developing circuits with small signal op amps ...

Page 5

... TYPICAL PERFORMANCE GRAPHS QUIESCENT CURRENT VS SUPPLY VOLTAGE 0 100 200 300 400 TOTAL SUPPLY VOLTAGE, (V) QUIESCENT CURRENT VS TEMPERATURE -40 - 100 120 CASE TEMPERATURE HARMONIC DISTORTION 10pF 32Ω LOAD ±Vs = ±60V 100 1k 30k 30 10k 100 1000 10000 FREQUENCY, F(Hz) PAD113 500 www.Thaler.com 5 ...

Page 6

... =85 C 100 400 ( Ω ) 1kHz sine clipped by current limit into 250Ω load S TYPICAL PERFORMANCE GRAPHS SMALL SIGNAL PHASE RESPONSE 50k 100000 100k 1000000 1M 10000000 10M FREQUENCY, F(Hz) TEMPERATURE OUTPUT 2 1 -40 - 100 120 O SUBSTRATE TEMPERATURE, C PAD113 www.Thaler.com 6 ...

Page 7

... SHUTDOWN RECOVERY The oscilloscope display at the left shows a view of a 5kHz, 1A p-p amplifier output signal on Ch2 resuming normal operation after a shutdown signal on Ch1 go high (not shutdown). The output signal resumes normal operation after a delay of about 1mS. PAD113 www.Thaler.com 7 ...

Page 8

... Pulse Response, 20kHz, 200Vp-p G=-50, Cc=10pF Pulse Response, Overloaded Input, 20kHz, 200Vp-p G=-50, Cc=10pF Thaler Corp 2015 N Forbes Blvd Tucson AZ 85745 USA Phone (800)827-6006 or (520)882-4000 Fax (520)770-9222 Web Site: PERFORMANCE GRAPHS CONTINUED Pulse Response, 20kHz, 20Vp-p G=-50, Cc=10pF 10kHz sine into 250Ω load, G=-50,C C PAD113 =10pF www.Thaler.com 8 ...

Page 9

... The safe operating area (SOA power amplifier is its single most important specification. The SOA graph presented above serves as a first approximation to help you decide if the PAD113 will meet the demands of your application. But a more accurate determination can be reached by making use of the PAD Power spreadsheet which can be found in the Thaler website ...

Page 10

... HIGH VOLTAGE OPERATIONAL AMPLIFIER Thaler Corp 2015 N Forbes Blvd Tucson AZ 85745 USA Phone (800)827-6006 or (520)882-4000 Fax (520)770-9222 Web Site: PAD113 DIMENSIONAL INFORMATION www.Thaler.com 10 ...

Page 11

... Thaler Corp 2015 N Forbes Blvd Tucson AZ 85745 USA Phone (800)827-6006 or (520)882-4000 Fax (520)770-9222 Web Site +IL -IL OUT 9,12 21 FIGURE 1. 4-WIRE CURRENT LIMIT 5.1k 2N2907 SHUTDOWN MONITOR H=SHUTDOWN 2N2222 10k TRANSISTOR CIRCUIT 5.1k FIGURE 2. APPLICATION CIRCUITS SHUTDOWN MONITOR H=SHUTDOWN PAD113 www.Thaler.com 11 ...

Page 12

... HIGH VOLTAGE OPERATIONAL AMPLIFIER Thaler Corp 2015 N Forbes Blvd Tucson AZ 85745 USA Phone (800)827-6006 or (520)882-4000 Fax (520)770-9222 Web Site: 10k 2200pF TMP GND SD 2200pF FIGURE 3 MONITORING TMP AND SD APPLICATION CIRCUITS TMP MONITOR MONITOR OUTPUTS PAD113 www.Thaler.com 12 ...

Page 13

... Values for resistors R1-R7 and R be calculated using the downloaded from the Thaler web site. Thaler Corp 2015 N Forbes Blvd Tucson AZ 85745 USA Phone (800)827-6006 or (520)882-4000 Fax (520)770-9222 Web Site: FIGURE 5 PAD Power™ Excel spreadsheet that can be PAD113 APPLICATION CIRCUITS can S www.Thaler.com 13 ...

Related keywords