TS20 Unisonic Technologies, TS20 Datasheet
TS20
Available stocks
Related parts for TS20
TS20 Summary of contents
Page 1
... The operating temperature range varies with the voltage supply. The UTC TS20 can be used over a range of -55°C to +130°C with a supply voltage of 2.7V to 5.5V.For applications with a supply voltage of 2.4V, the UTC TS20 can be used over a temperature range of -30° ...
Page 2
... TS20 PIN CONFIGURATIONS PIN DESCRIPTION PIN NAME TYPE 1 NC — 2 GND I OUT GND I/O UNISONIC TECHNOLOGIES CO., LTD www.unisonic.com.tw Preliminary PIN DESCRIPTION No Connection. (Must be connected to ground or left floating) Ground. (Should be connected to pin 5. May be left floating, if desired) Voltage Output. Supply Voltage. (Bypass to GND with a 0.1uF capacitor) Ground ...
Page 3
... TS20 BLOCK DIAGRAM UNISONIC TECHNOLOGIES CO., LTD www.unisonic.com.tw Preliminary CMOS Ver.A ...
Page 4
... TS20 ABSOLUTE MAXIMUM RATING PARAMETER Power Supply Voltage Output Voltage Output Current Input Current at any pin Junction Temperature Operating Temperature Storage Temperature Note: Absolute maximum ratings are those values beyond which the device could be permanently damaged. Absolute maximum ratings are stress ratings only and functional device operation is not implied. ...
Page 5
... TS20 ELECTRICAL CHARACTERISTICS (Cont Note1 (−3.88x10 xT )+ (−1.15x10 OUT Note2: Accuracy is defined as the error between the measured and calculated output voltage at the specified conditions of voltage, current, and temperature (expressed in˚C). Note3: Nonlinearity is defined as the deviation of the calculated output-voltage-versus-temperature curve from the best-fit straight line, over the temperature range specified. Note4: Linear Equation: ...
Page 6
... TS20 TYPICAL APPLICATIONS CIRCUITS - (-3.88*10 *T )+(-1.15*10 *T)+1.8639 (T=temperature in degrees Celsius) Note: OUT T = -1481.96+ 2.1962* Temperature(T) +130°C +100°C +80°C +30°C +25°C UNISONIC TECHNOLOGIES CO., LTD www.unisonic.com.tw Preliminary 2 -2 (1.8639 OUT 6 3.88*10 Typical V Temperature(T) OUT 303mV 0°C 675mV -30°C 919mV -40°C 1515mV -55°C 1574mV ...
Page 7
... TS20 TYPICAL CHARACTERISTICS UTC assumes no responsibility for equipment failures that result from using products at values that exceed, even momentarily, rated values (such as maximum ratings, operating condition ranges, or other parameters) listed in products specifications of any and all UTC products described or contained herein . UTC products are not designed for use in life support appliances, devices or systems where malfunction of these products can be reasonably expected to result in personal injury ...