VCD30 CUI INC, VCD30 Datasheet - Page 2

no-image

VCD30

Manufacturer Part Number
VCD30
Description
Dc-dc Converter
Manufacturer
CUI INC
Datasheet
PART NUMBER: VCD30 series
NOTES:
INPUT
input filter
OUTPUT
voltage accuracy
voltage balance (dual)
transient response: single output: 25% step load change
external trim adj. range
ripple & noise
temperature coefficient
short circuit protection
line regulation
load regulation
GENERAL SPECIFICATIONS
efficiency
isolation voltage
isolation resistance
switching frequency
case grounding
operating temperature range
case temperature
cooling
storage temperature
safety
EMI/RFI
dimensions
case material
1. Measured from high line to low line
2. Measured from full load to 1/4 load
input voltage range
20050 SW 112
1
2
dual output: FL~1/2L, ±1% error band
20MHz BW
single/dual
triple
single/dual
triple
th
Ave. Tualatin, Oregon 97062
single output
dual +output
triple, 5V
12V/15V
-output
phone 503.612.2300 fax 503.612.2382
12V:
24V:
48V:
DESCRIPTION: DC/DC converter
black coated copper with non-conductive base
±2.0% max.
±2.0% max.
±3.0% max.
±2.0% max.
±5.0% max.
±1.0%max
<500µS
<500µS
±10%
10mV RMS., max
75mV p-p, max
±0.02%/°C
continuous
±0.5% max.
±1.0% max.
±1.0% max.
±5.0% max.
see table
500VDC min.
10
300KHz, Typical
connected to output common
-25°C to +71°C
100°C max.
free-air convection
-55°C to +105°C
UL 60950-1 file # E222736
six sided continuous shield
2x2x0.4 inches
(50.8x50.8x10.2mm)
9-18V
18-36V
36-72V
Pi type
9
Ohm min.
rev.
page
date
08/2007
2 of 3