104AT-2 Semitec, 104AT-2 Datasheet - Page 39

no-image

104AT-2

Manufacturer Part Number
104AT-2
Description
AT thermistor, 100KOhm
Manufacturer
Semitec
Datasheet
Reliability
ZENAMIC
Mechanical
Environmental
Characteristics
Robustness of
Terminations
(Tensile)
Robustness of
Terminations
(Bending)
Vibration
Solderability
Resistance to
Soldering Heat
High Temperature
Storage/Dry Heat
Humidity
(Steady State)
Temperature
Cycle
High Temperature
Load/
Dry Heat Load
Damp Heat Load/
Humidity Load
Low Temperature
Storage/Cold
After gradual applying of the force specified below and keeping the unit fixed
for 10 seconds, the terminal shall be visually examined for any damage.
The unit shall be secured with its terminal kept vertical and the force
specified below shall be applied in the axial direction.
The terminal shall gradually be bent by 90 in one direction, then 90 in the
opposite direction, and again back to the original position.
The damage of the terminal shall be visually examined.
After repeated applying of a single harmonic vibration (amplitude:0.75mm,
double amplitude:1.5mm) with 1 minute vibration frequency cycle (10 Hz to
55 Hz to 10Hz) to each of three perpendicular directions for 2 hours.
Thereafter, the unit shall be visually examined.
After dipping the terminals to a depth of approxirnately 3 mm from the body
in a soldering bath of 235 5 C for 2 0.5seconds, the terminal shall be
visually examined.
After each lead shall be dipped into a solder bath of 260 5 C to a point
2.0 to 2.5mm from the body of the unit, using shielding board (t 1.5mm),
be held there for 10 1s (5 series:5 1s) and then be stored at room
temperature and normal humidity for 1 to 2 hours.
The change of V
The specimen shall be subjected to 125 2 C for 1000 hours in a
thermostatic bath without load and then stored at room temperature and
normal humidity for 1 to 2 hours. Thereafter, the change of V
measured.
The specimen shall be subjected to 40 2 C, 90 to 95% RH for 1000 hours
without load and then stored at room temperature and normal humidity for 1
The following temperature cycle shall be repeated five times and then stored
at room temperature and normal humidity for 1 to 2 hours. The change of
After being continuously applied the Maximum Allowable Voltage at 85
2 C for 1000 hours, the specimen shall be stored at room temperature and
normal humidity for 1 to 2 hours. Thereafter, the change of V
measured.
The specimen shall be subjected to 40 2 C, 90 to 95% RH and the
Maximum Allowable Voltage for1000 hours and then stored at room
temperature and normal humidity for 1 to 2 hours. Thereafter, the change of
V
The specimen shall be subjected to
and then stored at room temperature and normal humidity for 1 to 2 hours.
Thereafter, the change of V
Terminal diameter
Terminal diameter
Step
to 2 hours. Thereafter, the change of V
V
1
2
3
4
CmA
0.6mm, 0.8mm
1.0mm
1.0mm
CmA
0.6mm, 0.8mm
shall be measured.
and mechanical damage shall be examined.
Room temperature
125 2
Room temperature
Temperature( C)
40 3
CmA
and mechanical damage shall be examined.
Force
Force
19.6N(2.0kgf)
9.8N(1.0kgf)
CmA
9.8N(1.0kgf)
4.9N(0.5kgf)
Test Methods
shall be measured.
40 2 C without load for1000 hours
Period(minutes)
CmA
30 3
15 3
30 3
15 3
shall be measured.
CmA
CmA
shall be
shall be
No remarkable
mechanical damage
Approximately 95% of
the terminals shall be covered
uniformly with new solder
No remarkable
mechanical damage
No remarkable
mechanical damage
V
V
V
V
V
V
V
CmA
CmA
CmA
CmA
CmA
CmA
CmA
/V
/V
/V
/V
/V
/V
/V
Criterion
CmA
CmA
CmA
CmA
CmA
CmA
CmA
5%
5%
5%
5%
10%
10%
5%
39