35 000
3.17. Mating
3.18. Mating Dimension
The dimension needed to ensure full mating of connectors must be considered when determining location. The
mated dimension of the connectors is provided in Figure 26.
3.19. Disassembly
The connectors must be unmated by unthreading the coupling locking ring until the connectors disconnect. Pull
the connectors straight apart. To avoid damage to the soldered connections, DO NOT pull on the wires.
3.20. Repair/Replacement
4. QUALIFICATION
Metal–Shell Micro Circular Connectors are not required to be agency approved.
5. TOOLING
No tooling is required for assembly of the Metal–Shell Micro Circular Connectors with the exception of shield
termination tooling, crimp ferrule, Band–It, or equivalent. Tool information and instructions are provided with the
shield termination product.
16
Metal-Shell Micro Circular Connectors
CAUTION
CAUTION
of 17
D. Panel Seals
Two types of panel seals are available for your production requirements. The closed cell neoprene sponge
(black) seal is available for rear panel–mounting as well as the flourosilicone o–ring (blue) panel seal.
Contact the Product Information number at the bottom of page 1 for specific part numbers and sizes of the
panel seals.
!
!
1. The mating faces of the receptacle assembly and plug assembly must face each other with the
alignment features located in the proper position. Refer to Figure 24.
2. The mating face of the plug assembly must be inserted into the mating face of the receptacle
assembly, then the coupling locking ring must be threaded on the receptacle threads until the plug
connector bottoms inside the receptacle assembly.
Connectors should be handled only by the metal shell to avoid deformation, contamination, or damage to the contact
solder joints.
Damaged product should not be used. If damaged wires are evident, they must be removed (by standard desoldering
methods) from the connector and replaced. If a damaged contact or connector is evident, the connector must be
replaced.