BTS 716GB Infineon Technologies, BTS 716GB Datasheet

no-image

BTS 716GB

Manufacturer Part Number
BTS 716GB
Description
Manufacturer
Infineon Technologies
Datasheet

Specifications of BTS 716GB

Packages
PG-DSO-20
Channels
4.0
Ron @ Tj = 25°c
140.0 mOhm
Recommended Operating Voltage Min.
5.5 V
Recommended Operating Voltage Max.
40.0 V
Il(sc)
9.0 A
Smart High-Side Power Switch
BTS716GB
Product Summary
Package
P-DSO-20
PG-DSO20
Block Diagram
Data Sheet
1
V1.0, 2007-05-13

Related parts for BTS 716GB

BTS 716GB Summary of contents

Page 1

Product Summary • • • • • • • • • • • • • • • • • • • • • • • • Data Sheet Smart High-Side Power Switch Ω Ω Ω  Block Diagram 1 BTS716GB ...

Page 2

IN4 Data Sheet control and protection circuit of channel 2 control and protection circuit of channel 3 control and protection circuit of channel 4 2 Smart High-Side Power Switch BTS716GB V1.0, 2007-05-13 ...

Page 3

Pin Definitions and Functions Pin Symbol Function 1,10, V Positive power supply voltage. Design the bb 11,12, wiring for the simultaneous max. short circuit 15,16, currents from channel and also for low 19,20 thermal resistance 3 IN1 ...

Page 4

Parameter Supply voltage (overvoltage protection see page 6) Supply voltage for full short circuit protection T = -40 ...+150°C j,start Load current (Short-circuit current, see page 6) ) Load dump protection 2 V LoadDump = 2 Ω ...

Page 5

Parameter and Conditions Thermal resistance junction - soldering point 7)8) junction – ambient cooling area Electrical Characteristics Parameter and Conditions -40...+150° unless otherwise specified j bb Load Switching ...

Page 6

Parameter and Conditions, = -40...+150° unless otherwise specified j bb Operating Parameters Operating voltage ) Undervoltage switch off 10 not tested, specified by design: ) Overvoltage protection ...

Page 7

Parameter and Conditions -40...+150° unless otherwise specified j bb Reverse Battery ) 16 Reverse battery voltage Drain-source diode voltage = - 2 +150° Diagnostic Characteristics Open load ...

Page 8

Truth Table Channel 1 and 2 Channel 3 and 4 (equivalent to channel 1 and 2) Normal operation Open load Overtemperature L = "Low" Level X = don't care H = "High" Level Status signal valid after the time delay ...

Page 9

Input circuit (ESD protection), The use of ESD zener diodes as voltage clamp at DC conditions is not recommended. Status output, ST1/2 or ST3/4 ESD-Zener diode: 6.1 V typ., max 0.3 mA 1.6 mA. The use of ESD ...

Page 10

GND disconnect with GND pull up Any kind of load > GND IN IN(T+) Due to V > low signal available. GND ST V disconnect with energized inductive bb load For ...

Page 11

Typ. on-state resistance high L R [mOhm] ON Typ. standby current , I 9...34 V, IN1,2,3,4 = low EE RII ...

Page 12

Timing diagrams All channels are symmetric and consequently the diagrams are valid for channel 1 to channel 4 Figure 1a: V turn on: bb Figure 2a: Switching a resistive load, turn-on/off time and slew rate definition: on Data Sheet Figure ...

Page 13

Figure 3b: Turn on into short circuit: shut down by overtemperature, restart by cooling (two parallel switched channels 1 and 2) ST1 and ST2 have to be configured as a 'Wired OR' function ST1/2 with a single pull-up resistor. Figure ...

Page 14

Package Outlines Figure 1 PG-DSO-20 (Plastic Dual Small Outline Package) (RoHS-compliant) To meet the world-wide customer requirements for environmentally friendly products and to be compliant with government regulations the device is available as a green product. Green products are RoHS-Compliant ...

Page 15

Revision History Version Date Changes V1.0 2007-05-13 Creation of the green datasheet. First page : Adding the green logo and the AEC qualified Adding the bullet AEC qualified and the RoHS compliant features Package page Modification of the package to ...

Page 16

... Infineon Technologies Office. Infineon Technologies Components may only be used in life-support devices or systems with the express written approval of Infineon Technologies failure of such components can reasonably be expected to cause the failure of that life-support device or system affect the safety or effectiveness of that device or system. Life support devices or systems are intended to be implanted in the human body support and/or maintain and sustain and/or protect human life ...

Related keywords