MAX4511 Maxim, MAX4511 Datasheet
![no-image](/images/no-image-200.jpg)
MAX4511
Available stocks
Related parts for MAX4511
MAX4511 Summary of contents
Page 1
... On-resistance is 175Ω max and is matched between switches to 10Ω max. The off-leakage current is only 0.5nA at +25°C and 10nA at +85°C. The MAX4511 has four normally closed switches. The MAX4512 has four normally open switches. The MAX4513 has two normally closed and two normally open switches ...
Page 2
... V+ or V-, or ±40V with Stresses beyond those listed under “Absolute Maximum Ratings” may cause permanent damage to the device. These are stress ratings only, and functional operation of the device at these or any other conditions beyond those indicated in the operational sections of the specifications is not implied. Exposure to absolute maximum rating conditions for extended periods may affect device reliability. ELECTRICAL CHARACTERISTICS— ...
Page 3
Quad, Rail-to-Rail, Fault-Protected, ELECTRICAL CHARACTERISTICS—Dual Supplies (continued +15V -15V, GND = 0V PARAMETER FAULT (V+ = +15V -15V, unless otherwise noted.) COM_ Output Leakage Current, Supplies On NO_ or ...
Page 4
Quad, Rail-to-Rail, Fault-Protected, SPST Analog Switches ELECTRICAL CHARACTERISTICS—Dual Supplies (continued +15V -15V, GND = 0V PARAMETER SYMBOL POWER SUPPLY Power-Supply Range V Supply Current V- Supply Current GND Supply ...
Page 5
Quad, Rail-to-Rail, Fault-Protected, ELECTRICAL CHARACTERISTICS—Single +12V Supply (V+ = +10.8V to +13.2V MIN PARAMETER SYMBOL ANALOG SWITCH Fault-Protected Analog V Signal Range Fault-Free Analog Signal Range V Non-Protected Analog Signal Range (COM_ Output) ...
Page 6
... ON ON(MAX) ON(MIN) Note 5: Leakage parameters are 100% tested at maximum rated hot temperature and guaranteed by correlation at T Note 6: Guaranteed by design. Note 7: Off isolation = 20 log10 [ V COM_ Note 8: Between any two switches. Note 9: Leakage testing for single-supply operation is guaranteed by testing with dual supplies. ...
Page 7
Quad, Rail-to-Rail, Fault-Protected, __________________________________________Typical Operating Characteristics (T = +25°C, unless otherwise noted.) A SWITCH ON-RESISTANCE vs. V (DUAL SUPPLIES) COM 350 V+ = +5V 300 V- = -5V 250 V+ = +12V V+ = +10V V- = -12V V- = ...
Page 8
... The MAX4511/MAX4512/MAX4513 are fault-protected CMOS analog switches with unusual operation and construction. Traditional fault-protected switches are constructed by three series FETs. This produces good off characteristics, but fairly high on-resistance when the signals are within about 3V of each supply rail. As ...
Page 9
... V- -ESD DIODE Figure 1. Block Diagram Overview of MAX4511/MAX4512/MAX4513 The MAX4511/MAX4512/MAX4513 differ considerably from traditional fault-protection switches, with several advantages. First, they are constructed with two paral- lel FETs, allowing very low on-resistance when the switch is on. Second, they allow signals on the NC_ or ...
Page 10
... Fault-Protection Voltage and Power Off The maximum fault voltage on the NC_ or NO_ pins is ±36V with power applied and ±40V with power off. The MAX4511/MAX4512/MAX4513 are not lightning arrestors or surge protectors. Exceeding the fault-protection voltage limits on NO_ or NC_, even for very short periods, can cause the device to fail ...
Page 11
... The MAX4511/MAX4512/MAX4513 operate with bipolar supplies between ±4.5V and ±18V. The V+ and V- sup- plies need not be symmetrical, but their difference can not exceed the absolute maximum rating of 44V. The MAX4511/MAX4512/MAX4513 operate from a sin- gle supply between +9V and +36V when V- is connect GND. High-Frequency Performance In 50Ω ...
Page 12
... V+ ADDRESS SELECT V- IS CONNECTED TO GND (0V) FOR SINGLE-SUPPLY OPERATION. Figure 5. COM_, NO_, NC_ Capacitance 12 ______________________________________________________________________________________ Test Circuits/Timing Diagrams (continued) V IN_ V OUT C L 1000pF V+ V+ NO_ MAX4511 NC_ MAX4512 MAX4513 COM_ IN_ V- GND ∆ OUT OUT ∆ THE MEASURED VOLTAGE DUE TO CHARGE- OUT TRANSFER ERROR Q WHEN THE CHANNEL TURNS OFF ...
Page 13
... Quad, Rail-to-Rail, Fault-Protected, V+ 10nF V+ MAX4511 MAX4512 MAX4513 IN_ ADDRESS SELECT NO_, NC_ GND 10nF MEASUREMENTS ARE STANDARDIZED AGAINST SHORT AT SOCKET TERMINALS. OFF ISOLATION IS MEASURED BETWEEN COM_ AND “OFF” NO_ OR NC_ TERMINALS. ON LOSS IS MEASURED BETWEEN COM_ AND “ON” NO_ OR NC_ TERMINALS. ...
Page 14
... Quad, Rail-to-Rail, Fault-Protected, SPST Analog Switches Chip Topographies MAX4511 NC1 COM1 IN1 IN2 COM2 V- GND NC4 COM4 IN4 IN3 COM3 0.086" (2.261mm) MAX4512 NO1 COM1 IN1 IN2 COM2 V- GND NO4 COM4 IN4 IN3 COM3 0.086" (2.261mm) TRANSISTOR COUNT: 139 SUBSTRATE CONNECTED TO: V+ ...
Page 15
... Quad, Rail-to-Rail, Fault-Protected, (The package drawing(s) in this data sheet may not reflect the most current specifications. For the latest package outline information www.maxim-ic.com/packages TOP VIEW D e FRONT VIEW ______________________________________________________________________________________ SPST Analog Switches DIM ...
Page 16
... Quad, Rail-to-Rail, Fault-Protected, SPST Analog Switches (The package drawing(s) in this data sheet may not reflect the most current specifications. For the latest package outline information www.maxim-ic.com/packages.) 16 ______________________________________________________________________________________ Package Information (continued) ...
Page 17
... For the latest package outline information www.maxim-ic.com/packages.) Maxim cannot assume responsibility for use of any circuitry other than circuitry entirely embodied in a Maxim product. No circuit patent licenses are implied. Maxim reserves the right to change the circuitry and specifications without notice at any time. ...