MAX16913A Maxim, MAX16913A Datasheet - Page 5

no-image

MAX16913A

Manufacturer Part Number
MAX16913A
Description
The MAX16913/MAX16913A high-voltage high-side current-sense switches feature internal current limiting to prevent system damage due to fault conditions
Manufacturer
Maxim
Datasheet

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
MAX16913AGEE
Manufacturer:
MAXIM/美信
Quantity:
20 000
Part Number:
MAX16913AGEE+T
Manufacturer:
MAXIM
Quantity:
15
Part Number:
MAX16913AGEE/V+T
Manufacturer:
MAXIM
Quantity:
328
1, 8, 9, 16
SHDN
SC
OL
IN
PIN
3, 4
5, 6
10
11
12
13
14
15
2
7
MAX16913 Functional Diagram
MAX16913
NAME
SHDN
AOUT
SENS
GND
OUT
N.C.
OLT
REF
OL
SC
IN
DRIVER AND
CONTROL
FET
_______________________________________________________________________________________
Ground
Input Voltage. Bypass IN to GND with a low-ESR ceramic capacitor with a minimum value of 0.1µF.
Input to Current-Sense Amplifier. Connect the sense resistor between SENS and IN.
Switch Output
Active-High Control Input. Drive SHDN low to turn on the device.
No Connection. Not internally connected.
Open-Load Threshold Setting Input. A resistive divider between REF, OLT, and GND sets the open-load
current threshold (MAX16913A). For the MAX16913, connect OLT to GND.
+3V Nominal Reference Output. Use a resistive divider between REF, OLT, and ground to set the open-load
current threshold (MAX16913A). The output impedance of this voltage regulator is 5kΩ.
Current-Monitor Voltage Output. AOUT can be used to measure the load current by means of an external
ADC. The output impedance is 5kΩ.
Open-Drain Open-Load Indicator Output. OL goes low when the load current is lower than the open-load
current threshold, or when there is a short-to-battery fault. Connect OL to a 10kΩ pullup resistor. See Table 1.
Open-Drain Short-Circuit Indicator Output. SC goes low when the load current is greater than the short-circuit
current threshold or when there is a short-to-battery fault. Connect SC to a 10kΩ pullup resistor. See Table 1.
CURRENT
SENSE
V
V
REF
REF2
SENS
OLT
CHARGE
PUMP
REF
OT
Remote Antenna Current-Sense
GND
OUT
AOUT
REF
Amplifier and Switches
SHDN
FUNCTION
SC
OL
IN
MAX16913A Functional Diagram
MAX16913A
DRIVER AND
CONTROL
FET
CURRENT
SENSE
OLT
V
V
REF
REF2
SENS
Pin Description
CHARGE
PUMP
REF
OT
GND
OUT
AOUT
REF
5

Related parts for MAX16913A