MAXQ3180 Maxim, MAXQ3180 Datasheet - Page 34

no-image

MAXQ3180

Manufacturer Part Number
MAXQ3180
Description
The MAXQ3180 is a dedicated electricity measurement front-end that collects and calculates polyphase voltage, current, power, energy, and many other metering and power-quality parameters of a polyphase load
Manufacturer
Maxim
Datasheet

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
MAXQ3180-RAN
Manufacturer:
MAXIM/美信
Quantity:
20 000
Part Number:
MAXQ3180-RAN+
Manufacturer:
SANKEN
Quantity:
23 000
Part Number:
MAXQ3180-RAN+T
Manufacturer:
MAXIM
Quantity:
10
Part Number:
MAXQ3180-RBN
Manufacturer:
MAXIM/美信
Quantity:
20 000
Low-Power, Multifunction, Polyphase AFE
34
Bit:
Name:
Reset:
Bit:
Name:
Reset:
BIT
7:3
15
14
13
12
11
10
______________________________________________________________________________________
9
8
2
1
0
EDSPRDY When set, this flag causes the IRQ pin to become active.
ECHSCH
EDSPOR
EDCHR
EDCHA
EPWRF
ENOZX
EEOVF
NAME
EOC
EUV
EOV
EDSPOR
15
0
7
0
When set, this flag causes the IRQ pin to become active.
When set, this flag causes the IRQ pin to become active when the direction of reactive energy flow has
been observed to have changed (that is, from capacitive to inductive or from inductive to capacitive).
When set, this flag causes the IRQ pin to become active when the direction of real energy flow has
been observed to have changed (that is, from toward the load to away from the load, or from away from
the load to toward the load).
When set, this flag causes the IRQ pin to become active when the MAXQ3180 has failed to detect zero
crossings on one or more voltage channels for at least one DSP cycle.
When set, this flag causes the IRQ pin to become active when the absolute instantaneous voltage
level in one or more voltage channels failed to exceed the trip level set in the UVLVL (Undervoltage
Level) register for one DSP cycle.
When set, this flag causes the IRQ pin to become active when the absolute instantaneous voltage
level in one or more voltage channels has exceeded the trip level set in the OVLVL (Overvoltage Level)
register.
When set, this flag causes the IRQ pin to become active when absolute instantaneous current in one
or more current channels has exceeded the trip level set in the OCLVL (Overcurrent Level) register.
Reserved.
When set, this flag causes the IRQ pin to become active when one or more energy accumulators have
an overflow condition from their MSB.
When set, this flag enables the IRQ pin to become active when a CHKSUM change is detected.
When set, this flag causes the IRQ pin to become active when a power-supply failure is imminent and
the supervisory processor should begin taking steps to save its state and prepare for a loss of power.
EDSPRDY
14
0
6
0
EDCHR
13
0
5
0
EDCHA
12
0
4
0
Interrupt Mask Register (IRQ_MASK) (0x006)
FUNCTION
ENOZX
11
0
3
0
EEOVF
EUV
10
0
2
0
ECHSCH
EOV
9
0
1
0
EPWRF
EOC
8
0
0
0

Related parts for MAXQ3180