DS2430A Maxim, DS2430A Datasheet - Page 7

no-image

DS2430A

Manufacturer Part Number
DS2430A
Description
The DS2430A 256-bit 1-Wire® EEPROM identifies and stores relevant information about the product to which it is associated
Manufacturer
Maxim
Datasheet

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
DS2430A
Manufacturer:
DALLAS
Quantity:
80
Part Number:
DS2430A
Manufacturer:
DALLAS
Quantity:
5 510
Part Number:
DS2430A+
Manufacturer:
MAXIM
Quantity:
4 000
Part Number:
DS2430AP
Manufacturer:
MAX
Quantity:
20 000
Part Number:
DS2430AP+T
Manufacturer:
NEC
Quantity:
1 680
Part Number:
DS2430AP+T&R
Manufacturer:
Maxim
Quantity:
20 000
Part Number:
DS2430AP+T&R
Manufacturer:
MAXIM
Quantity:
10 000
Part Number:
DS2430AP+T&R
0
Part Number:
DS2430AX-SP
Manufacturer:
GRAYHILL
Quantity:
500
DS2430A
MEMORY FUNCTION FLOW CHART Figure 6 (continued)
WRITE APPLICATION REGISTER [99h]
This command is essentially the same as the Write Scratchpad command, but it addresses the 64-bit
register scratchpad. After issuing the command code, the master must provide a 1-byte address, followed
by the data to be written. The DS2430A automatically increments the address after every byte it receives.
After receiving the data byte for address 07h, the address counter wraps around to 00h for the next byte
and writing continues until the master sends a Reset Pulse. The Write Application Register command can
be used as long as the application register has not yet been locked. If issued for a device with the
application register locked, the data written to the register scratchpad will be lost.
READ STATUS REGISTER [66h]
The status register is a means for the master to find out whether the application register has been
programmed and locked. After issuing the read status register command, the master must provide the
validation key 00h before receiving status information. The two least significant bits of the 8-bit status
register are 0 if the application register was programmed and locked; all other bits always read 1. The
master may finish the read status command by sending a Reset Pulse at any time.
7 of 19

Related parts for DS2430A