1600636-6 TE Connectivity, 1600636-6 Datasheet - Page 3

1600636-6

Manufacturer Part Number
1600636-6
Description
Manufacturer
TE Connectivity
Datasheets

Specifications of 1600636-6

Product Series
XL
Connector Type
Connector Assembly
Termination Style
Panel
Mating Type
Blindmate
Guides
With
Mating Functionality
Mate First-Break Last
Voltage Rating (signal) (vac)
60
Voltage Rating (power) (vac)
300
Voltage Rating (power) (vdc)
200
Sequencing
Yes
Connector Configuration Orientation
Right-to-Left
Centerline, Dc Module (mm [in])
6.35 [0.250]
Centerline, Ac Module (mm [in])
7.62 [0.300]
Centerline, Matrix (mm [in])
2.54 x 2.54 [.100 x .100]
Contact Type
Socket
Connector Style
Receptacle
Housing Material
Thermoplastic - GF
Total Number Of Dc Power
12
Total Number Of Ac Power
4
Total Number Of Signal
24
Connector Contact Configuration (no. Of Pos./type)
4/AC Power, 24/Signal, 12/DC Power
Rohs/elv Compliance
RoHS compliant, ELV compliant
Lead Free Solder Processes
Not relevant for lead free process
Rohs/elv Compliance History
Always was RoHS compliant
Application Use
Cable-to-Board
Rev C
Contact resistance at rated current,
power contacts.
Insulation resistance.
Withstanding voltage.
Temperature rise vs current.
Vibration, random.
Mechanical shock.
Durability.
Mating force.
Test Description
0.7 milliohm maximum, end of life.
500 megohms minimum for signal
contacts.
1000 megohms minimum for power
contacts.
1 minute hold with no breakdown or
flashover.
30
specified current.
No discontinuities of 1 microsecond
or longer duration.
See Note.
No discontinuities of 1 microsecond
or longer duration.
See Note.
See Note.
Average mating force for power
contacts shall be less than 28
ounces per contact.
Average mating force for signal
contacts shall be less than 6
ounces per contact.
/
C maximum temperature rise at
Wire Size
(AWG)
10
14
8
MECHANICAL
Figure 3 (cont)
Requirement
(amperes DC)
Test Current
35
20
15
EIA-364-6.
At rated DC test current.
EIA-364-21.
Test between adjacent contacts.
EIA-364-20, Condition I.
1000 volts DC at sea level for
signal contacts.
2500 volts DC at sea level for
power contacts.
Test between adjacent contacts.
EIA-364-70, Method 1.
Stabilize at a single current level
until 3 readings at 5 minute
intervals are within 1
EIA-364-28, Test Condition VII,
Condition E.
Subject mated specimens to 4.90
G's rms between 20-500 Hz.
Fifteen minutes in each of 3
mutually perpendicular planes.
EIA-364-27, Method A.
Subject mated specimens to 50 G's
half-sine shock pulses of 11
milliseconds duration. Three
shocks in each direction applied
along 3 mutually perpendicular
planes, 18 total shocks.
EIA-364-9.
Mate and unmate specimens for
250 cycles at a maximum rate of
500 cycles per hour.
EIA-364-13.
Measure force necessary to mate
specimens at a maximum rate of .5
inch per minute. Measure signal
contacts using gage 1.
See Figure 5.
Procedure
/
C .
108-2157
3 of 9

Related parts for 1600636-6