Page 1
... Application Specification (MICTOR SB Vertical Connectors for Surface Mount ● Technology (SMT) Printed Circuit (PC) Board Applications) 501-616: Qualification Test Report ● 2.2. Industry Standards EIA-364: Electrical Connector/Socket Test Procedures Including Environmental Classifications ! ● EIA-638: Surface Mount Solderability Test 3. REQUIREMENTS 3.1. Design and Construction Product shall be of the design, construction and physical dimensions specified on the applicable product drawing ...
Page 2
... EIA-638. Subject contacts to solderability. EIA-364-28, Test Condition V. Subject specimens to 7.56 G's rms between 50 to 2000 Hz. One hour in each of 3 mutually perpendicular planes. EIA-364-27, Method A. Subject specimens to 50 G's half- sine shock pulses of 11 milliseconds duration. Three shocks in each direction applied along 3 mutually perpendicular planes, 18 total shocks ...
Page 3
... NOTE tests as specified in the Product Qualification and Requalification Test Sequence shown in Figure 2. The use of alternate gold plating thickness parts (gold flash or 30 microinch gold) can be expected to have the same electrical, mechanical and dielectric performance characteristics. Decision to use such parts should depend on customer’s need for alternate durability or environmental performance characteristics ...
Page 4
... Specimen Selection Specimens shall be prepared in accordance with applicable Instruction Sheets and shall be selected at random from current production. Test groups 1 and 2 each shall consist of 3 mated pairs (plug and receptacle) of vertical assemblies. Test group 3 shall consist of 5 unmounted, mated pairs (plug and receptacle) of vertical assemblies with housings fully populated with signal contacts and bus bars ...
Page 5
... Quality Conformance Inspection The applicable quality inspection plan shall specify the sampling acceptable quality level to be used. Dimensional and functional requirements shall be in accordance with the applicable product drawing and this specification. Low Level Contact Resistance Measurement Points Rev B Figure 3 108-2139 ...