ADM1062 Analog Devices, ADM1062 Datasheet - Page 24

no-image

ADM1062

Manufacturer Part Number
ADM1062
Description
Manufacturer
Analog Devices
Datasheet

Specifications of ADM1062

# Supplies Monitored
10
Volt Monitoring Accuracy
1%
# Output Drivers
10
Fet Drive/enable Output
Both
Voltage Readback
12-bit ADC
Supply Adj/margining
12-bit ADC+6 DACs
Package
40 ld LFCSP ,48 ld TQFP

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
ADM1062ASUZ
Manufacturer:
Analog Devices Inc
Quantity:
10 000
Part Number:
ADM1062ASUZ
Manufacturer:
ADI/亚德诺
Quantity:
20 000
Part Number:
ADM1062ASUZ-REEL7
Manufacturer:
Analog Devices Inc
Quantity:
10 000
ADM1062
TEMPERATURE MEASUREMENT SYSTEM
The ADM1062 contains an on-chip, band gap temperature
sensor whose output is digitized by the on-chip, 12-bit ADC.
Theoretically, the temperature sensor and the ADC can measure
temperatures from −128°C to +128°C with a resolution of 0.125°C.
Because this exceeds the operating temperature range of the device,
local temperature measurements outside this range are not possible.
Temperature measurements from −128°C to +128°C are possible
using a remote sensor. The output code is in offset binary format,
with −128°C given by Code 0x400, 0°C given by Code 0x800,
and +128°C given by Code 0xC00.
As with the other analog inputs to the ADC, a limit register is
provided for each of the temperature input channels. Therefore,
a temperature limit can be set such that if it is exceeded, a warning
is generated and available as an input to the sequencing engine.
This enables users to control their sequence or monitor functions
based on an overtemperature or undertemperature event.
REMOTE TEMPERATURE MEASUREMENT
The ADM1062 can measure the temperature of a remote diode
sensor or diode-connected transistor connected to Pin DN and
Pin DP (Pin 37 and Pin 38 on the LFCSP package and Pin 44
and Pin 45 on the TQFP package).
The forward voltage of a diode or diode-connected transistor
operated at a constant current exhibits a negative temperature
coefficient of about −2 mV/°C. Unfortunately, the absolute value
of V
is required to null it, making the technique unsuitable for mass
production. The technique used in the ADM1062 is to measure
the change in V
currents.
The change in V
where:
k is Boltzmann’s constant.
q is the charge on the carrier.
T is the absolute temperature in Kelvin.
N is the ratio of the two currents.
BE
Δ V
varies from device to device, and individual calibration
BE
= kT / q × ln ( N )
BE
BE
when the device is operated at two different
is given by
TRANSISTOR
SENSING
REMOTE
CPU
Figure 36. Signal Conditioning for Remote Diode Temperature Sensors
THERM DA
THERM DC
DP
DN
I
DIODE
BIAS
Rev. C | Page 24 of 36
N × I
I
BIAS
LOW-PASS FILTER
f
V
C
DD
= 65kHz
Figure 36 shows the input signal conditioning used to measure the
output of a remote temperature sensor. This figure shows the
external sensor as a substrate transistor provided for temperature
monitoring on some microprocessors, but it could equally be
a discrete transistor such as a 2N3904 or 2N3906.
If a discrete transistor is used, the collector is not grounded and
should be linked to the base. If a PNP transistor is used, the base
is connected to the DN input, and the emitter is connected to
the DP input. If an NPN transistor is used, the emitter is connected
to the DN input, and the base is connected to the DP input.
Figure 34 and Figure 35 show how to connect the ADM1062 to
an NPN or PNP transistor for temperature measurement. To
prevent ground noise from interfering with the measurement,
the more negative terminal of the sensor is not referenced to
ground but is biased above ground by an internal diode at the
DN input.
Figure 34. Measuring Temperature Using an NPN Transistor
Figure 35. Measuring Temperature Using a PNP Transistor
2N3904
2N3906
NPN
PNP
V
V
OUT+
OUT–
DP
DN
DP
DN
ADM1062
ADM1062
TO ADC

Related parts for ADM1062