ADP8866 Analog Devices, ADP8866 Datasheet - Page 36

no-image

ADP8866

Manufacturer Part Number
ADP8866
Description
Charge Pump Driven 9-Channel LED Driver with Automated LED Lighting Effects
Manufacturer
Analog Devices
Datasheet

Specifications of ADP8866

Vin Range
2.5 to 5.5V
Vout (v)
4.3 to 5.5
Synchronous
No
Package
20-Lead LFCSP
Led Configuration
Parallel
Topology
Capacitive
I2c Support
Yes
Max Iout (ma)
25mA
Brightness Control
I2C
Peak Efficiency (%)
92%
Switching Frequency
1MHz
ADP8866
Table 47.
Designation
SC4OFF
SC3OFF
SC2OFF
SC1OFF
1
Independent Sink 6 Off Timer (OFFTIMER6)—Register 0x1E
Table 48. OFFTIMER6 Bit Map
Bit 7
Reserved
Table 49.
Bit Name
N/A
SC6OFF
1
2
3
An independent sink remains on continuously when it is enabled and SCxOFF is 00 (disabled).
An independent sink remains on continuously when it is enabled and SCxOFF is 00 (disabled).
Setting SCxOFF to 0 seconds is not recommended if the SCFO fade-out time is also set to 0 seconds.
Setting SCxOFF to off causes the LED to be held off indefinitely. This is useful for setting up a blink sequence that runs once and then goes to off.
Bit
[7:6]
[5:4]
[3:2]
[1:0]
Bit 6
Bit No.
7
[6:0]
Description
SC4 off time. When the SC off time is disabled, the SC remains on while enabled. When the SC off time is set to any
other value, the ISC turns off for the off time (per the following listed times) and then turns on according to the
SCON setting.
00 = off time disabled.
01 = 0.6 sec.
10 = 1.2 sec.
11 = 1.8 sec.
SC3 off time. When the SC off time is disabled, the SC remains on while enabled. When the SC off time is set to any
other value, the ISC turns off for the off time (per the following listed times) and then turns on according to the
SCON setting.
00 = off time disabled.
01 = 0.6 sec.
10 = 1.2 sec.
11 = 1.8 sec.
SC2 off time. When the SC off time is disabled, the SC remains on while enabled. When the SC off time is set to any
other value, the ISC turns off for the off time (per the following listed times) and then turns on according to the
SCON setting.
00 = off time disabled.
01 = 0.6 sec.
10 = 1.2 sec.
11 = 1.8 sec.
SC1 off time. When the SC off time is disabled, the SC remains on while enabled. When the SC off time is set to any
other value, the ISC turns off for the off time (per the following listed times) and then turns on according to the
SCON setting.
00 = off time disabled.
01 = 0.6 sec.
10 = 1.2 sec.
11 = 1.8 sec.
Description
Reserved.
SC6 off time. When the SC off time is disabled, the SC remains on while enabled. When the SC off time is set to
any other value, the ISC turns off for the off time (per the following listed times) and then turns on according to
the SCON setting.
0000 = disabled
0000001 = 0.0 sec
0000010 = 0.1 sec.
0000011 = 0.2 sec.
1111110 = 12.5 sec.
1111111 = off
Bit 5
1
3
.
1
.
2
.
Bit 4
Rev. 0 | Page 36 of 52
Bit 3
SC6OFF
Bit 2
Bit 1
Bit 0