AD9785 Analog Devices, AD9785 Datasheet - Page 31

no-image

AD9785

Manufacturer Part Number
AD9785
Description
Dual 12-Bit 800 MSPS DAC with Low Power 32-Bit Complex NCO
Manufacturer
Analog Devices
Datasheet

Specifications of AD9785

Resolution (bits)
12bit
Dac Update Rate
800MSPS
Dac Settling Time
n/a
Max Pos Supply (v)
+3.47V
Single-supply
No
Dac Type
Current Out
Dac Input Format
Par

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
AD9785BSVZ
Manufacturer:
Analog Devices Inc
Quantity:
135
Part Number:
AD9785BSVZ
Manufacturer:
Analog Devices Inc
Quantity:
10 000
Company:
Part Number:
AD9785BSVZ
Quantity:
2
Part Number:
AD9785BSVZRL
Manufacturer:
Analog Devices Inc
Quantity:
10 000
The interrupt control register comprises two bytes located at Address 0x09. Bits [11:10] and Bits [7:3] are read-only bits that indicate the
current status of a specific event that may cause an interrupt request (IRQ pin active low). These bits are controlled via the digital logic
and are read only via the serial port. Bits [1:0] are the IRQ mask (or enable) bits, which are writable by the user and can also be read back.
Table 19. Interrupt Control Register
Address
0x09
Bit
[15:13]
[12]
[11]
[10]
[9:8]
[7]
[6]
[5]
[4]
[3]
[2]
[1]
[0]
Name
Reserved
Clear lock indicator
Sync lock lost status
Sync lock status
Reserved
Data timing error IRQ
Sync timing error IRQ
Data timing error type
Sync timing error type
PLL lock indicator
Reserved
Data port IRQ enable
Sync port IRQ enable
Reserved for future use.
Writing a 1 to this bit clears the sync lock lost status bit. This bit does not automatically
reset itself to 0 when the reset is complete.
When high, this bit indicates that the device has lost synchronization. This bit is latched
and does not reset automatically after the device regains synchronization. To reset this
bit to 0, a 1 must be written to the clear lock indicator bit.
When this bit is low, the device is not synchronized. When this bit is high, the device is
synchronized.
Reserved for future use.
0: Default. No setup or hold time error has been detected via the input data port
setup/hold error checking logic.
1: A setup or hold time error has been detected via the input data port setup/hold error
checking logic.
0: Default. No setup or hold time error has been detected via the multichip
synchronization receive pulse setup/hold error checking logic.
1: A setup or hold time error has been detected via the multichip synchronization
receive pulse setup/hold error checking logic.
0: Default. A hold error has been detected via the input data port setup/hold error
checking logic. This bit is valid only if the data timing error IRQ bit (Bit 7) is set.
1: A setup error has been detected via the input data port setup/hold error checking
logic. This bit is valid only if the data timing error IRQ bit (Bit 7) bit is set.
0: Default. A hold error has been detected via the multichip synchronization receive
pulse setup/hold error checking logic. This bit is valid only if the sync timing error IRQ
bit (Bit 6) is set.
1: A setup error has been detected via the multichip synchronization receive pulse
setup/hold error checking logic. This bit is valid only if the sync timing error IRQ bit
(Bit 6) is set.
0: Default. The PLL clock multiplier is not locked to the input reference clock.
1: The PLL clock multiplier is locked to the input reference clock.
Reserved for future use.
0: Default. The data IRQ bit (and the IRQ pin) are not enabled (masked) for any errors
that may be detected via the input data port setup/hold error checking logic.
1: The data IRQ bit (and the IRQ pin) are enabled and go active if a setup or hold error is
detected via the input data port setup/hold error checking logic.
0: Default. The sync IRQ bit (and the IRQ pin) are not enabled (masked) for any errors
that may be detected via the multichip synchronization receive pulse setup/hold error
checking logic.
1: The sync IRQ bit (and the IRQ pin) are enabled and go active if a setup or hold error
is detected via the multichip synchronization receive pulse setup/hold error checking
logic.
Description
Rev. A | Page 31 of 64
AD9785/AD9787/AD9788

Related parts for AD9785