5-440054-5 TE Connectivity, 5-440054-5 Datasheet - Page 6

5-440054-5

Manufacturer Part Number
5-440054-5
Description
Manufacturer
TE Connectivity
Datasheets

Specifications of 5-440054-5

Product Type
Connector
Connector Type
Header
Mount Angle
Vertical
Number Of Positions
15
Centerline (mm [in])
2.00 [0.079]
Number Of Rows
Single
Locking Interface
Without
Post Material
Brass
Post Plating
Tin
Pcb Mount Retention Type
Retention Leg(s)
Contact Type
Pin
Contact Termination Type
Through Hole
Connector Style
Plug
Housing Color
Natural
Ul Flammability Rating
UL 94V-0
Housing Material
Nylon 66
Rohs/elv Compliance
RoHS compliant, ELV compliant
Lead Free Solder Processes
Wave solder capable to 240°C
Rohs/elv Compliance History
Always was RoHS compliant
Packaging Method
Tube
4.
Rev
4.1 QUALIFICATION TESTING
4.2 RE-QUALIFICATION TESTING
4.3 ACCEPTANCE
4.4 QUALITY CONFORMANCE INSPECTION
If changes significantly affecting form, fit or function are made to product or
manufacturing process, product assurance shall coordinate re-qualification testing,
consisting of all or part of original testing sequence as determined by
development/product, quality and reliability engineering.
Acceptance is based on verification that product meets requirements Spelled in Table
2. Data attributed to equipment; test setup or operator deficiencies shall not disqualify
product. When product failure occurs, corrective action shall be taken and samples
resubmitted for qualification. Testing to confirm corrective action is required before
resubmit.
Applicable AMP quality inspection plan will specify sampling acceptable quality level to
be used.
applicable product drawing and this specification.
QUALITY ASSURANCE PROVISIONS
D
A. Test Specimens
The test specimens to be used for the performance evaluation testing, shall be
prepared in accordance with AMP Application Specification, 114-57011, Termination
AMP 2.0mm HPI CRIMP Connector, by using samples selected from the current
production at random, and conforming to the requirements of the applicable product
drawings.
B. Test Condition
Unless otherwise specified, all tests shall be performed under any combination of
the following test conditions:
Temperature
Relative Humidity
Atmospheric Pressure : 650 – 800 mmHg
Dimension and functional requirements shall be in accordance with
: 15 – 30° C
: 45 – 75%
108-57100
6 of 6

Related parts for 5-440054-5