... TYCO SPECIFICATIONS A. 109-1: General Requirements for Test Specifications B. 109 series: Test Specification as indicated in figure 2 (Comply with MIL-STD-202) C. Corporate Bulletin 401-76: Cross-reference between AMP test Specifications and Military or Commercial Documents. D. 114-57011: Application Specification. E. 501-57058: Test Report. ...
Page 2
... Table 2. All tests are performed at ambient environmental conditions per Tyco Specification 109-1 unless otherwise specified. Rev D 3A, 100 VAC / DC 1A, 250 VAC / DC AWG #24 — 3.0A AWG #26 — 2.0A AWG #28 — 1.5A AWG #30 — 1.0A AWG #30 -- #24 (0.05mm 0.9mm - 1.5mm 0.7mm – 0.8mm 108-57100 0.22mm ) ...
Page 3
... Final max) 2 2.5 0.8 0.6 3 3.0 0.8 0.6 4 3.5 1.0 0.8 5 4.0 1.0 0.8 6 4.5 1.2 1.0 7 5.0 1.2 1.0 8 5.5 1.4 1.2 9 6.0 1.4 1.2 10 6.5 1.6 1.4 11 7.0 1.6 1.4 12 7.5 1.8 1.6 13 8.0 1.8 1.6 14 8.5 2.0 1.8 15 9.0 2.0 1.8 16 9.5 2.0 1.8 Insertion Force Extraction Force 0.10kgf min (Initial) 0.7kgf max 0.08kgf min (Final) 108-57100 PROCEDURE Visually, inspected per applicable quality inspection plan. Subject mated contacts assembled in housing to closed circuit current of 10mA max at open circuit voltage of 20mV max ...
Page 4
... Subject mated connector assemblies to temperature life at 85° C±2° C 240hours. Subject mated connectors to steady state humidity at 40° C and 90- 95% R.H for 240hrs MIL-STD-202, Method 103, Condition B. Subject mated connector assemblies on 25 cycle -55 ° C and +85 ° C for 30 minutes each duration at temperature extremes ...
Page 5
... After 72 hours exposure in ammonia chamber with 25cc of 3% ammonia solution for every liter of chamber capacity Subject mated connectors to cold testing atmosphere at -25 ℃ ± 3 ℃ 48 hours. Termination resistance (low level) shall be met ...
Page 6
... A. Test Specimens The test specimens to be used for the performance evaluation testing, shall be prepared in accordance with AMP Application Specification, 114-57011, Termination AMP 2.0mm HPI CRIMP Connector, by using samples selected from the current production at random, and conforming to the requirements of the applicable product drawings ...