2-440054-2 TE Connectivity, 2-440054-2 Datasheet
2-440054-2
Specifications of 2-440054-2
Related parts for 2-440054-2
2-440054-2 Summary of contents
Page 1
... TYCO SPECIFICATIONS A. 109-1: General Requirements for Test Specifications B. 109 series: Test Specification as indicated in figure 2 (Comply with MIL-STD-202) C. Corporate Bulletin 401-76: Cross-reference between AMP test Specifications and Military or Commercial Documents. D. 114-57011: Application Specification. ...
Page 2
... Applicable Printed Circuit Board A. Board Thickness: 0.8mm - 1.6mm B. Hole Diameter: 3.4. PERFOMANCE AND TEST DESCRIPTION The product is designed to meet the electrical, mechanical and environmental performance requirements specified in Table 2. All tests are performed at ambient environmental conditions per Tyco Specification 109-1 unless otherwise specified. Rev D ...
Page 3
... Subject terminated connector and header to mate and unmate to measure the force required to engage and disengage by operating at a rate of 25mm a minute. Subject terminated contact and pin to mate and unmate to measure the force required to engage and disengage by operating at a rate of 25mm a minute ...
Page 4
... Subject mated connectors to steady state humidity at 40° C and 90- 95% R.H for 240hrs MIL-STD-202, Method 103, Condition B. Subject mated connector assemblies on 25 cycle -55 ° C and +85 ° C for 30 minutes each duration at temperature extremes. MIL-STD-202, Method 107, Condition A Subject mated/ unmated connectors to 5% salt concentration for 48 hours. ...
Page 5
... After 72 hours exposure in ammonia chamber with 25cc of 3% ammonia solution for every liter of chamber capacity Subject mated connectors to cold testing atmosphere at -25 ℃ ± 3 ℃ 48 hours. Termination resistance (low level) shall be met ...
Page 6
... ACCEPTANCE Acceptance is based on verification that product meets requirements Spelled in Table 2. Data attributed to equipment; test setup or operator deficiencies shall not disqualify product. When product failure occurs, corrective action shall be taken and samples resubmitted for qualification. Testing to confirm corrective action is required before resubmit ...