Description
Power Module: dc-dc Converter, 38 Vdc to 60 Vdc Input, 12 Vdc Output, 50 W
Manufacturer
Lucent Technologies
Datasheet

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
FE150B
Manufacturer:
LUCENT
Quantity:
27
Part Number:
FE150B
Manufacturer:
SEMIKRON
Quantity:
492
Part Number:
FE150B
Manufacturer:
LUCENT
Quantity:
20 000
June 1998
The FE050B, FE100B, and FE150B Power Modules use
advanced, surface-mount technology and deliver high-quality,
compact, dc-dc conversion at an economical price.
Applications
Options
Description
The FE050B, FE100B, and FE150B Power Modules are dc-dc converters that operate over an input voltage
range of 38 Vdc to 60 Vdc and provide a precisely regulated dc output. The outputs are fully isolated from the
inputs, allowing versatile polarity configurations and grounding connections. The modules have maximum
power ratings from 50 W to 150 W at a typical full-load efficiency of 86%.
Built-in filtering, for both the input and output of each device, eliminates the need for external filters. Two or more
modules may be paralleled with forced load sharing for redundant or enhanced power applications. The
package, which mounts on a printed-circuit board, accommodates a heat sink for high-temperature applications.
Redundant and distributed power architectures
Telecommunications
Output voltage set-point adjustment (trim)
FE050B, FE100B, FE150B Power Modules: dc-dc Converters;
38 Vdc to 60 Vdc Input, 12 Vdc Output; 50 W to 150 W
Features
* UL is a registered trademark of Underwriters Laboratories, Inc.
† CSA is a registered trademark of Canadian Standards Association.
‡ TÜV is a registered trademark of Technischer Überwachungs-
Verein.
High efficiency: 86% typical
Parallel operation with load sharing
Low profile: 12.7 mm (0.5 in.)
Complete input and output filtering
Within FCC requirements for Telecom
Constant frequency
Case ground pin
Input-to-output isolation
Remote sense
Remote on/off
Short-circuit protection
Output overvoltage clamp
UL * Recognized, CSA
Certified, TÜV
Licensed

Related parts for FE150B

FE150B Summary of contents

Page 1

... Output voltage set-point adjustment (trim) Description The FE050B, FE100B, and FE150B Power Modules are dc-dc converters that operate over an input voltage range of 38 Vdc to 60 Vdc and provide a precisely regulated dc output. The outputs are fully isolated from the inputs, allowing versatile polarity configurations and grounding connections. The modules have maximum power ratings from 150 typical full-load effi ...

Page 2

... Parameter Operating Input Voltage Maximum Input Current ( V): I FE050B FE100B FE150B Inrush Transient Input Reflected-ripple Current, Peak-to-peak ( MHz, 12 µH source impedance) (See Figure 9.) Input Ripple Rejection (120 Hz) Fusing Considerations CAUTION: This power module is not internally fused. An input line fuse must always be used. ...

Page 3

... FE100B FE150B Efficiency ( ° max C see Figure 3—Figure 9.): FE050B FE100B FE150B Dynamic Response ( A/10 µ Figure 6 and Figure 7.): Load Change from I = 50 Peak Deviation Settling Time (V < 10% of peak deviation) O Load Change from I ...

Page 4

... Min Typ Max 2,000,000 — — 200 (7) Min Typ Max 0 — 1.2 — — 1.0 — — 18 — — 50 — — — 1.2 90 — 110 — — 20 13.2 14.7 16.0 Lucent Technologies Inc. Unit pF M Unit hours g (oz.) Unit µ nom % I O, max V ...

Page 5

... Data Sheet June 1998 Characteristic Curves The following figures provide typical characteristics for the FE150B Power Module. The FE050B and FE100B char- acteristics are similar to the FE150B characteristics provided here, scaled by power level where appropriate INPUT VOLTAGE, V Figure 1 ...

Page 6

... Vdc to 60 Vdc Input, 12 Vdc Output 150 W Characteristic Curves (continued TIME µs/div) Figure 5. Typical FE150B Output Ripple Voltage at Room Temperature Input, and 12.5 A Output 100 mV TIME, t (50 µs/div) Figure 6. Typical FE150B Transient Response to Step Decrease in Load from 50% to 25% ...

Page 7

... BNC socket. Position the load between in.) and in.) from the module. Figure 11. Peak-to-Peak Output Noise Measurement Test Setup Lucent Technologies Inc. 38 Vdc to 60 Vdc Input, 12 Vdc Output 150 W Design Considerations Input Source Impedance The power module should be connected to a low CURRENT ac-impedance input source ...

Page 8

... SENSE(–) V (+) V (+) LOAD (–) V (– CONTACT AND DISTRIBUTION LOSSES Single-Module Remote-Sense Operation ) between the trim-up ) increases the output O, adj 1.25 17 ---------------------------- - V 12 – O adj , ) between trim-down ) decreases the O adj , V – 1.25 17.8 O, adj = k ------------------------------------------------------- - 12 V – O, adj Lucent Technologies Inc. 1.2 V (+) and O 8-651 (C) ...

Page 9

... O I CONTACT RESISTANCE Figure 15. Circuit Configuration to Trim Down Output Voltage Lucent Technologies Inc. 38 Vdc to 60 Vdc Input, 12 Vdc Output 150 W Adjustment Without TRIM Pin The output voltage can be adjusted by placing an external resistor (R V (+) terminals (see Figure 16). By adjusting R ...

Page 10

... Heat is removed by conduc- tion, convection, and radiation to the surrounding environment. Proper cooling can be verified by mea- suring the case temperature. Peak temperature occurs at the position indicated in Figure 18 (3.0) 18 (0.7) Lucent FE150B9 DC-DC Power Module CASE IN:DC 48V, 3.7A ON/OFF + IN MADE IN USA – Protected by U.S. Patents: 5,036,452 5,179,365 Note: Top view, measurements shown in millimeters and (inches) ...

Page 11

... HEAT SINK tance. 1 in. HEAT SINK To choose a heat sink, determine the power dissipated as heat by the unit for the particular application. Figure 22 shows typical heat dissipation for a range of output currents and three voltages for the FE050B, FE100B, and FE150B. 1.5 2.0 2.5 (400) (500) 8-696 (C).a NO HEAT SINK 0 ...

Page 12

... Use Figure 20 and Figure 21 to determine air velocity (continued) for the 0.5 inch heat sink. The minimum airflow neces- sary for the FE150B module depends on heat sink fin (continued) orientation and is shown below: 0.4 m/s (80 ft./min.) (oriented along width) 0.45 m/s (90 ft./min.) (oriented along length) ...

Page 13

... Lucent Technologies Inc. 38 Vdc to 60 Vdc Input, 12 Vdc Output 150 W 121.9 (4.80) Lucent FE150B9 DC-DC Power Module IN:DC 48V, 3.7A OUT:DC 12V, 12.5A 150W MADE IN USA TUV Rheinland Protected by U.S. Patents: 5,036,452 5,179,365 55.63 (2.190) 55.63 (2.190) FOR OPTIONAL HEAT SINK MOUNTING #4-40 THD 4.6 (0.18) DEEP 6 PLCS 0 ...

Page 14

... Yes 150 W Yes 100 W No 150 W No Data Sheet June 1998 TRIM OPTION ONLY 35.56 30.48 (1.400) 25.40 (1.200) 20.32 (1.000) (0.800) 12.2 8-719 (C).m Device Comcode Code FE050B9 Not Available FE100B9 Not Available FE150B9 Not Available FE050B 106258304 FE100B 106258353 FE150B 105775530 Lucent Technologies Inc. ...

Page 15

... Data Sheet June 1998 Notes Lucent Technologies Inc. 38 Vdc to 60 Vdc Input, 12 Vdc Output 150 W 15 ...

Page 16

... ITALY: (39) 2 6608131 (Milan), SPAIN: (34) 1 807 1441 (Madrid) Lucent Technologies Inc. reserves the right to make changes to the product(s) or information contained herein without notice. No liability is assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information. ...