MGDS-10-H-C/T List of Unclassifed Manufacturers, MGDS-10-H-C/T Datasheet

no-image

MGDS-10-H-C/T

Manufacturer Part Number
MGDS-10-H-C/T
Description
Manufacturer
List of Unclassifed Manufacturers
Datasheet
• 28Vdc input compliant with MIL-STD-704 D/E
• Low profile : 0,33 “ (8.5mm)
• Nominal power of 10 W without derating
• Wide temperature range : -40°C/+105°C case
• High efficiency up to 83 %
• Soft start
• Galvanic isolation 1.500 VDC
• Integrated LC EMI filter
• Permanent short circuit protection
• Parallel operation master/slave
• No optocoupler for high reliability
REDEFINING THE SOURCE OF POWER
©
Gaia Converter FC97-010.08/06 Revision P
The MGDM-10 series is a full family of high perfor-
mance DC/DC low profile power modules designed
for aerospace, military and high-end industrial ap-
plications. These modules use a high frequency
fixed switching technic at 480 KHz providing ex-
cellent reliability, low noise characteristics, high
power density and a low profile package. Standard
models are available with nominal input voltages
as 5, 12 or 28 volts in range of 4,5-5,5 9-36 or 16-
40 volts. The series include single bi and triple
output voltage choices of 3,3, 5, 12, 15, +/-5, +/
-12, +/-15 or +/-24 volts. No external heatsink is
required for the MGDM-10 series to supply 10W
output power over the case temperature range of
-40°C up to 105°C.
All the modules are designed with LC network filters
to minimize reflected input current ripple and out-
put voltage ripple.
1-General
2-Product Selection
Master converter :
Single output model
Bi output model
Triple output model
Slave converter :
Single output model
(/T) : option for -55°C start up operating temperature.
(/S) : option for screening and serialization
C : 4,5-5,5 VDC
H :
J : 16-40 VDC
Permanent
9-36 VDC
* Consult factory for details
Input Voltage Range
: MGDS-10-
: MGDB-10-
: MGDT-10-
: MGDE-10-
Hi-Rel DC/DC CONVERTER
40 VDC/100 ms*
50 VDC/100 ms*
For locations, phone, fax, E-Mail see back cover
MGDM-10 : 10W POWER
Transient
n/a
Metallic Case - 1.500 VDC Isolation
The modules include a soft-start, an input
undervoltage lock-out, a permanent short circuit
protection and an output overvoltage protection
to ensure efficient module protections.
The soft-start allows current limitation and
eliminates inrush current during start-up. The short
circuit protection completely protects the module
against short-circuits of any duration by a shut-
down and restores to normal when the overload is
removed.
The design has been carried out with surface mount
components and is manufactured in a fully
automated process to guarantee high quality. Each
module is tested and burned in with a GAIA
Converter automated test equipment before and
after encapsulation.The modules are potted with
an excellent thermal conductive compound and
packaged in a metallic case to ensure the module’s
integrity under high temperature conditions.
Single, Bi & Triple Outputs
(/T) and/or (/S)
(/T) and/or (/S)
(/T) and/or (/S)
(/T) and/or (/S)
B : 3.3 VDC
C : 5 VDC or +/-5VDC
E : 12 VDC or +/-12VDC
F : 15 VDC or +/-15VDC
CE : 5 VDC and +/-12 VDC
CF : 5 VDC and +/-15 VDC
I : +/-24 VDC
Output
Hi-Rel
Grade
4

Related parts for MGDS-10-H-C/T

MGDS-10-H-C/T Summary of contents

Page 1

... All the modules are designed with LC network filters to minimize reflected input current ripple and out- put voltage ripple. 2-Product Selection Master converter : Single output model : MGDS-10- Bi output model : MGDB-10- Triple output model : MGDT-10- Slave converter : Single output model : MGDE-10- (/T) : option for -55° ...

Page 2

... MGDB-10-C MGDS-10-H MGDS-10-H MGDS-10-H MGDS-10-H MGDB-10-H MGDB-10-H MGDB-10-H MGDT-10-H- MGDT-10-H- MGDS-10-J MGDS-10-J MGDS-10-J MGDS-10-J MGDB-10-J MGDB-10-J MGDB-10-J MGDB-10-J MGDT-10-J- MGDT-10-J- ...

Page 3

... Maximum W Maximum A Maximum A Maximum A Maximum A Maximum mVpp Maximum mVpp Maximum mVpp Maximum % Maximum % Typical % Maximum µF Maximum µF For locations, phone, fax, E-Mail see back cover Hi-Rel Grade Single Output MGDS-10 10 4,5-5,5 9-36 16- 16-45 / 40/0,1 50/0 4,3 8 ...

Page 4

Electrical Characteristics (continued) Data are valid at +25°C, unless otherwise specified. Parameter Conditions Input Nominal input voltage Full temperature range Permanent input Full temperature range voltage range (Ui) Extended permanent input Full temperature range voltage range (Consult factory) Transient ...

Page 5

Electrical Characteristics (continued) Data are valid at +25°C, unless otherwise specified. Parameter Conditions Input Nominal input voltage Full temperature range Permanent input Full temperature range voltage range (Ui) Extended permanent input Full temperature range voltage range (Consult factory) Transient ...

Page 6

... Figure 11 : Typical load regulation characteristics at nominal input 13,20 13,00 12,80 12,60 12,40 12,20 12,00 11,80 0 100 200 300 400 500 600 700 800 900 Output Current (mA) (MGDS-10-J-E module) For locations, phone, fax, E-Mail see back cover Hi-Rel Grade Figure 3 : Typical efficiency versus load at nominal input input ...

Page 7

Switching Frequency Parameter Switching frequency 5- Isolation Parameter Electric strength test voltage Electric strength test voltage between outputs (for dual and triple outputs) Isolation resistance 6- Protection Functions Characteristics Input undervoltage lock-out (UVLO) Output short circuit protection (SCP) Output ...

Page 8

Electromagnetic Interference Electromagnetic Interference requirements according to MIL-STD-461C/D/E standards can be easily achieved as indicated in the following section. The following table resumes the different sections covered by these standards. Standard Requirements Conducted emission (CE) : Low frequency High ...

Page 9

Thermal Characteristics Characteristics Operating ambient temperature range at full load Operating case temperature range at full load Storage temperature range Thermal resistance Note * : The upper temperature range depends on configuration, the user must assure a max. case ...

Page 10

Environmental Qualifications The modules have been subjected to the following environmental qualifications. Characteristics Conditions Climatic Qualifications Duration Life at high Temperature / status of unit temperature Altitude level C Duration Altitude Climb up Stabilization Status of unit Number of ...

Page 11

Description of Protections 11-1 Input Undervoltage Lock-out (UVLO) The input undervoltage lock-out protection device turns- on and turns-off the output voltage when the input bus voltage reaches the undervoltage lock-out threshold. There is no hysteresis cycle at turn-on and ...

Page 12

... A «master» module will synchronize a «slave» module to the same clock allowing a current share in between modu- les through the «gate» pin. A master module MGDS-10 can drive slave modules MGDE-10 . © Gaia Converter FC97-010.08/08 Revision P MGDM-10 Series ...

Page 13

Dimensions Dimension are given in mm (inches). Tolerance : +/- 0,2 mm (+/- 0.01 “) unless otherwise indicated. Weight : 20 grams (0.7 Ozs) max. 40 (1.58") Single & Bi & Tri output models 5 min 26,20 (0.20") (1.03") ...

Page 14

For more detailed specifications and applications information, contact : International Headquarters Marketing and Sales department Address : B. 33186 LE HAILLAN - FRANCE Tel (33)-5-57-92-12-80 Fax : + (33)-5-57-92-12-89 Information given in this datasheet is believed ...