112S12VFI Martek Power, 112S12VFI Datasheet

no-image

112S12VFI

Manufacturer Part Number
112S12VFI
Description
Manufacturer
Martek Power
Datasheet
www.martekpower.com
1111 Knox Street
100VFI series
The 100VFI Model 1.5 watt DC/DC’s are specially designed to
provide ultra-high levels of isolation 6000VDC in a low profile
24 pin DIP package. The series consists of 18 models with
input voltages of 5V, 12V and 15V, and offers regulated
output voltages of 5V, 12V, 15V, ±5V, ±12V and ±15V.
The 100VFI series is an excellent selection for railroad/
transportation equipment, medical equipment subsystems,
process/machine control equipment and automatic test
instrumentation.
O O
Martek Power reserves the right to change specifications without notice.
D D
Output Voltage Set Point
Output Voltage Balance
(Duals)
Line Regulation
Load Regulation (5 Vout)
Load Regulation (±5 Vout)
Load Regulation (12,±12 Vout)
Load Regulation (15,±15 Vout)
Ripple/Noise
Ripple/Noise
Overload Protection
Short Circuit Protection
Temperature Coefficient
U U T T P P U U T T
E E S S C C R R I I P P T T I I O O N N S S
Single & Dual Output
C C
DC/DC Converter
H H A A R R A A C C T T E E R R I I S S T T I I C C S S
Torrance
Min
120
±0.01
±2.0
±0.5
±1.2
±7.0
±8.0
±6.0
±4.0
Typ
30
Max
±10.0
±12.0
±0.02
±4.0
±2.0
±1.5
±8.0
±6.0
40
50
CA 90502
mV p-p, Over Line,
% Output voltage at
nominal line & FL
% Equal Output
Loads
%; % Change /
Percentage change
in Input
voltage
% Output voltage
measured from FL
to 20% load
mV p-p, Nom.Line
@FL, 20MHz B.W.,
using 1 μf bypass
capacitor
Load & Temp., 20
MHz B.W.,
using 1 μf bypass
capacitor
%Rated Output Load
Continuous,
Automatic Recovery
% per degree C
Unit/Comments
USA
• •
• •
• •
• •
• •
• •
I I
F F
G G
Input Voltage
Input Fuse Requirements
Reverse Polarity Input Current
Short Circuit Input Power
Input Filter
Switching Frequency
Test Isolation Voltage
Rated Isolation Voltage
Isolation Resistance
Isolation Capacitance
MTBF (MIL-HBK-217F)
N N P P U U T T
E E A A T T U U R R E E S S
H H
U U p p t t o o 7 7 5 5 % % E E f f f f i i c c i i e e n n c c y y
S S i i n n g g l l e e a a n n d d D D u u a a l l O O u u t t p p u u t t , , 1 1 . . 5 5 w w a a t t t t c c o o n n v v e e r r t t e e r r
A A v v a a i i l l a a b b l l e e i i n n 5 5 , , 1 1 2 2 , , a a n n d d 1 1 5 5 V V D D C C I I n n p p u u t t s s
S S h h o o r r t t C C i i r r c c u u i i t t P P r r o o t t e e c c t t i i o o n n
L L o o w w I I s s o o l l a a t t i i o o n n C C a a p p a a c c i i t t a a n n c c e e
E E N N E E R R A A L L
Tel: +1 310 202 8820
5 VDC Input Models
12 VDC Input Models
15 VDC Input Models
5 VDC Input Models
12 VDC Input Models
15 VDC Input Models
I I G G H H
I I
C C
S S O O L L A A T T I I O O N N
H H A A R R A A C C T T E E R R I I S S T T I I C C S S
C C
H H A A R R A A C C T T E E R R I I S S T T I I C C S S
- - 6 6 0 0 0 0 0 0 V V D D C C
10,000
8,000
6,000
Min
10.8
13.5
Min
4.5
50
2
sales@martekpower.com
1000
Typ
250
250
Typ
12
15
10
5
Max
1000
13.2
16.5
Max
5.5
0.5
100
15
Pi Filter
mA; Slow blow type
mA; Slow blow type
mA; Slow blow type
Amp
mW
VDC, 1 minute
VDC, 1 minute
Mohm, 500VDC
pF, 100kHz, 1Volt
Million Hours,
+25
Benign
Unit/Comments
Unit/Comments
VDC
VDC
VDC
o
C, Ground
kHz
>> B-17

Related parts for 112S12VFI

112S12VFI Summary of contents

Page 1

... Ripple/Noise 30 Ripple/Noise Overload Protection 120 Short Circuit Protection Temperature Coefficient ±0.01 ±0.02 Martek Power reserves the right to change specifications without notice. 1111 Knox Street Torrance • • • ...

Page 2

...

Page 3

... Model Nominal Input Voltage (VDC) 105S5VFI 5 112S5VFI 5 115S5VFI 5 105D5VFI 5 112D5VFI 5 115D5VFI 5 105S12VFI 12 112S12VFI 12 115S12VFI 12 105D12VFI 12 112D12VFI 12 115D12VFI 12 105S15VFI 15 112S15VFI 15 115S15VFI 15 105D15VFI 15 112D15VFI 15 115D15VFI 15 1111 Knox Street ...

Page 4

Pout % 100 ...