PAH150S48-2.5 TDK Corporation, PAH150S48-2.5 Datasheet - Page 74

no-image

PAH150S48-2.5

Manufacturer Part Number
PAH150S48-2.5
Description
Manufacturer
TDK Corporation
Datasheet

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
PAH150S48-2.5
Manufacturer:
LAMBDA
Quantity:
1 000
Part Number:
PAH150S48-2.5
Quantity:
60
PAH
B-216
PAH
Be sure to take note of precautions and warnings indi-
cated in this manual when using this product. Improper us-
age may lead to electric shock or fire. Be sure to read this
instruction manual thoroughly before using this product.
● There are high voltage and high temperature components
● When the unit is operating, keep your hands and face away
● Confirm connections to input/output terminals and signal ter-
● Attach a fast blow type external fuse to each module to
● This power module is designed for professional installation
● Use isolated voltage by reinforced or double insulation as
within this product. Refrain from disassembling this product
or touching its internal components as this may lead to elec-
tric shock or burned.
from the unit. You may get injured by accident.
minals are correct as indicated in the instruction manual.
ensure safety operation and compliance to each safety stan-
dard approval.
within the end user equipment.
Caution
200H
Before Using This Power Module
Input and Output Terminal Configurations(Bottom View)
PAH200H Instruction Manual
1. Terminal Explanation
−Vin
+Vin
CNT
Bottom View
● PAH50S48 〜 200S48 Instruction Manual
● PAH300S24, 350S24 Instruction Manual
● PAH300S48, 350S48 Instruction Manual
−V
−V
+V
+V
−S
TRM
+S
● PAH450S48 Instruction Manual
● Do not inject abnormal voltage to output terminal and signal
● The application circuits and their parameter are for reference
● The information in this document is subject to change with-
● No part of this document may be copied or reproduced in
CE Marking, when applied to a product covered by instruction
manual, indicates compliance with the low voltage directive
which complies with EN60950
input power source.
terminal from the outside.
The injection of reverse voltage or over voltage exceeding
nominal output voltage to output terminals might cause
Damage to internal output capacitor (Functional Polymerized
Capacitor)
only. Be sure to verify effectiveness of application circuits
and their parameters before finalizing circuit design.
out prior notice. For actual design-in, please refer to the lat-
est publications of data sheet, etc., for the most up-to-date
specifications of the unit.
any for, or by any mean without prior written consent of Den-
sei-Lambda.
Note : CE Marking
● PAH75D Instruction Manual
[Input terminal ]
-Vin: -Input Terminal
CNT: ON/OFF Control Terminal
+Vin: +Input Terminal
[ Output terminal ]
-V:   -Output Terminal
-S:   -Remote Sensing Terminal
TRM: Output Voltage Trimming Terminal
+S:  +Remote Sensing Terminal
+V: +Output Terminal
Please ensure good connectivity to
minimize the connection resistance
for terminal +Vin, -Vin, +V and ‒V.
・All specifications are subject to change without notice.
B-169Page
B-177Page
B-182Page
B-190Page
B-199Page

Related parts for PAH150S48-2.5