DAS
INPUT
OUTPUT
PROTECTION
CIRCUIT AND
OTHERS
ISOLATION
ENVIRONMENT
SAFETY
OTHERS
SPECIFICATIONS
MODEL
MAX OUTPUT WATTAGE[W]
DC OUTPUT
*1
*2
*
H-72
Measured by attaching the electrolytic capacitor of 220mF at output.
Drift is the change in DC output for an eight hour period after a half-hour warm-up at 25C, with the input voltage held constant at the rated input/output.
Parallel operation with other model is not possible.
R
MODEL
VOLTAGE[V]
CURRENT[A]
EFFICIENCY[%]
LEAKAGE CURRENT[mA] 0.3max ( By UL , CSA , VDE and DEN-AN )
VOLTAGE[V]
CURRENT[A]
LINE REGULATION[mV]
LOAD REGULATION[mV] 40max
RIPPLE[mVp-p]
RIPPLE NOISE[mVp-p]
TEMPERATURE REGULATION[mV]
DRIFT[mV]
START-UP TIME[ms]
OUTPUT VOLTAGE ADJUSTMENT RANGE[V] Fixed ( TRM pin open ) t 10% adjustable by external VR
OUTPUT VOLTAGE SETTING[V] 4.85 - 5.35
OVERCURRENT PROTECTION Works over 105% of rating and recovers automatically
OVERVOLTAGE PROTECTION Works at 115 - 140% of rating
REMOTE SENSING
REMOTE ON/OFF
INPUT-OUTPUT
INPUT-FG
OUTPUT-FG
OPERATING TEMP. , HUMID.AND ALTITUDE -10 to +85 C ( Aluminum base plate ), 20 - 95%RH ( Non condensing ) ( Refer to DERATING CURVE ), 3 , 000m ( 10 , 000feet ) max
STORAGE TEMP. , HUMID.AND ALTITUDE -40 to +85 C , 20 - 95%RH ( Non condensing ), 9 , 000m ( 30 , 000feet ) max
VIBRATION
IMPACT
AGENCY APPROVALS
CASE SIZE/WEIGHT
COOLING METHOD
Power module type
DAS50
0 to +85 C
-10 - 0 C
0 to +85 C
-10 - 0 C
0 to +85 C 85max
-10 to +85 C 95max
* 1
* 1
* 1
* 1
* 2
DAS50F05
50
5V 10A
DAS50F05
DC88 - 370
0.5typ ( DCIN 130V , Io=100% ) 0.25typ ( DCIN 260V , Io=100% ) 1.30typ ( DCIN 48V , Io=100% ) 1.28typ ( DCIN 48V , Io=100% )
82typ
5
10
20max
80max
140max
150max
190max
20max
200max ( DCIN 88V , Io=100% )
Provided
Between RC and -side of input:short - 1.2V --- output ON , 2.4 - 5.5V ( or open ) --- output OFF , Compatible TTL
AC3 , 000V 1minute , Cutoff current = 10mA , DC500V 50M W min ( At Room Temperature ) AC500V 1minute , Cutoff current = 100mA , DC500V 50M W min ( At Room Temperature )
AC2 , 000V 1minute , Cutoff current = 10mA , DC500V 50M W min ( At Room Temperature ) AC500V 1minute , Cutoff current = 100mA , DC500V 50M W min ( At Room Temperature )
AC500V 1minute , Cutoff current = 100mA max , DC500V 50M W min ( At Room Temperature )
10 - 55Hz , 49.0m/s
196.1m/s
UL60950-1 , EN60950-1 , CSA C22.2 No.60950-1 Complies with DEN-AN Complies with UL60950-1 , CSA C22.2 No.60950-1 and EN60950-1
58 X 12.7 X 115mm ( W X H X D ) / 120g max
Conduction cooling ( e.g. heat radiation from the aluminum base plate to the attached heat sink )
2
( 20G ), 11ms , once each X , Y and Z axis
2
( 5G ), 3minutes period , 60minutes each along X , Y and Z axis
DAS50F12
50.4
12V 4.2A
DAS50F12
82typ
12
4.2
48max
100max
120max
160max
200max
230max
204max
228max
48max
11.4 - 12.6
1
Ordering information
DA
DAS50F24
50.4
24V 2.1A
DAS50F24
82typ
24
2.1
96max
150max
120max
160max
200max
230max
408max
456max
96max
22.8 - 25.2
2
S
3
50
DAS504805
50
5V 10A
DAS504805
DC36 - 72
80typ
5
10
20max
40max
80max
140max
150max
190max
85max
95max
20max
200max ( DCIN 36V , Io=100% )
4.85 - 5.35
4
O
1Series name
2Single output
3Output wattage
4Input voltage
5Output voltage
F :DC88 - 370V
48 :DC36 - 72V
5
DAS504812
50.4
12V 4.2A
DAS504812
82typ
12
4.2
48max
100max
120max
160max
200max
230max
210max
230max
48max
11.4 - 12.6
05