HD4812 Crydom Corporation, HD4812 Datasheet

no-image

HD4812

Manufacturer Part Number
HD4812
Description
Manufacturer
Crydom Corporation
Datasheet

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
HD4812
Manufacturer:
Crydom Co.
Quantity:
135
Part Number:
HD4812
Manufacturer:
CRYDOM
Quantity:
27
Part Number:
HD4812
Manufacturer:
CRYDOM
Quantity:
492
Part Number:
HD48125
Manufacturer:
Crydom Co.
Quantity:
135
Part Number:
HD48125
Manufacturer:
CRYDOM
Quantity:
27
OUTPUT SPECIFICATIONS 1
Operating Voltage (47-63 Hz) [Vrms]
Max. Load Current
Min. Load Current, [mArms]
Transient Overvoltage [Vpk]
Max. Surge Current, (16.6ms) [Apk]
Max. On-State Voltage Drop @ Rated Current [Vpk]
Thermal Resistance Junction to Case (R θJC ) [°C/W]
Maximum I 2 t for Fusing, (8.3 msec.) [A 2 sec]
Max. Off-State Leakage Current @ Rated Voltage [mArms]
Min. Off-State dv/dt @ Max. Rated Voltage [V/µsec]
Max. Turn-On Time
Max. Turn-Off Time
Power Factor (Min.) with Max. Load
INPUT SPECIFICATIONS 1
Control Voltage Range
Max. Reverse Voltage
Max. Turn-On Voltage
Min. Turn-Off Voltage
Nominal Input Impedance
Typical Input Current
G E N E R A L N O T E S
1
2
3
4
5
6
SERIES HA/HD.
REV. 030708
PAGE 1 OF 4
All parameters at 25°C unless otherwise specified.
Off-State dv/dt test method per EIA/NARM standard RS-443, paragraph 13.11.1
Heat sinking required, for derating curves see page 2.
24 Vac Input option, E suffix.
Turn-on time for random turn-on versions
is 0.02 msec (DC Control Models).
Input circuitry incorporates active current limiter.
3
5
M O D E L N U M B E R S
[Arms]
AC CONTROL
DC CONTROL
2
DC CONTROL
( D P R E F I X )
See Note
2.0 mA
3-32 Vdc
-32 Vdc
3.0 Vdc
1.0 Vdc
• Zero Voltage and Random
• Panel Mount
• 1200V Transient Capability
• Integrated Overvoltage
• 110 & 125A Models
Turn-On Switching
Protection by Automatic
Self Turn-On (Suffix P)
Available
For recommended applications and more information contact:
USA: Sales Support (877) 502-5500 Tech Support (877) 702-7700 FAX (619) 710-8540
Crydom Inc., 2320 Paseo de las Americas, Ste. 201, San Diego, CA 92154
Email: sales@crydom.com WEB SITE: http://www.crydom.com
UK: +44 (0)1202 606030 • FAX +44 (0)1202 606035 Crydom SSR Ltd., Arena Business Centre,
Holyrood Close, Poole, Dorset BH17 7FJ, Email: intsales@crydom.com.
GERMANY: +49 (0)180 3000 506
6
6
HA4812
HD4812
48-530
1200
1.48
140
500
1.7
0.5
12
40
81
10
2mA @ 120 Vrms, 4mA @ 240 Vrms
HA4825
HD4825
48-530
1200
1.02
250
260
500
1.7
0.5
25
40
10
90-280 Vrms (60Hz)
1/2 Cycle (DC Input), 10.0 msec (AC Input)
1/2 Cycle (DC Input), 40.0 msec (AC Input)
AC CONTROL
( A P R E F I X )
© 2008 CRYDOM Inc., Specifications subject to change without notice.
60K Ohms
90 Vrms
10 Vrms
Series
---
12-90Amp • 480 Vac - AC OUTPUT
Featuring state-of-the-art Surface
Mount Technology, these SPST-NO
relays deliver proven reliability in the
most demanding applications.
Output consists of an SCR AC switch
and is available in zero-cross, random
turn-on (phase controllable) and ver-
sions with either AC or DC input (coil)
control.
Manufactured in Crydom’s ISO 9001
Certified facility for optimum product
performance and reliability.
HA4850
HD4850
48-530
1200
1620
0.63
625
500
1.7
0.5
50
40
10
4
HA, HD
HA4875
HD4875
48-530
1200
1000
4150
0.31
500
1.7
0.5
AC CONTROL
75
40
10
3mA @ 24 Vrms
( E S U F F I X )
18-36 Vrms
9.0K Ohms
4.0 Vrms
18 Vrms
---
HA4890
HD4890
48-530
1200
1200
6000
0.28
500
1.7
0.5
90
40
10

Related parts for HD4812

HD4812 Summary of contents

Page 1

... PAGE • Zero Voltage and Random Turn-On Switching • Panel Mount • 1200V Transient Capability • Integrated Overvoltage Protection by Automatic Self Turn-On (Suffix P) • 110 & 125A Models Available AC CONTROL HA4812 HA4825 DC CONTROL HD4812 HD4825 48-530 12 40 1200 140 1.7 1. 500 0.5 ...

Page 2

AVAILABLE OPTIONS E 24 VAC Input (18-36 Vac) Example: HA4825E F Faston Terminals ( Amp Models) Example: HD4850F Input Status LED. G Example: HD4850G Note: Control Voltage Range 4.5-32 Vdc for DC Control Models. P Internal Overvoltage Protection. ...

Page 3

NO HEATSINK Load Current [Arms] Max Ambient Temp. [°C] SERIES HA/HD. REV. 030708 PAGE ...

Page 4

DANGER / PELIGRO / DANGER /GEFAHR / PERICOLO / PERIGO HAZARD OF RIESGO DE ELECTRIC DESCARGA SHOCK, ELECTRICA O EXPLOSION, EXPLOSION. OR ARC FLASH. • Desconectar • Disconnect all todos los power before suministros de installing or energia a este ...

Page 5

ANNEX – ENVIRONMENTAL INFORMATION: The environmental information disclosed in this annex including the EIP Pollution logo are in compliance with People’s Republic of China Electronic Industry Standard SJ/T11364 – 2006, Marking for Control of Pollution Caused by Electronic Information Products. ...

Related keywords