IRKL56/04A International Rectifier Corp., IRKL56/04A Datasheet
IRKL56/04A
Related parts for IRKL56/04A
IRKL56/04A Summary of contents
Page 1
THYRISTOR/ DIODE and THYRISTOR/ THYRISTOR Features High Voltage Industrial Standard Package Thick Al metal die and double stick bonding Thick copper baseplate UL E78996 approved 3500V isolating voltage RMS Mechanical Description The Generation V of Add-A-pak module combine the excellent ...
Page 2
IRK.41, .56 Series Bulletin I27131 rev. G 10/02 ELECTRICAL SPECIFICATIONS Voltage Ratings Voltage Type number Code peak reverse voltage peak reverse voltage - IRK.41/ . On-state Conduction Parameters IRK.41 I Max. average on-state ...
Page 3
Triggering Parameters IRK.41 P Max. peak gate power Max. average gate power 2.5 G(AV) I Max. peak gate current 2 Max. peak negative GM gate voltage V Max. gate voltage GT required to trigger I ...
Page 4
IRK.41, .56 Series Bulletin I27131 rev. G 10/02 Ordering Information Table Device Code IRK Module type 2 - Circuit configuration (See Circuit Configuration table below Current code * * 4 - ...
Page 5
IRK.41.. Series R (DC) = 0.46 K/W thJC 120 110 Conduction Angle 100 30° 60° 90° 120° Average On-state Current (A) Fig Current Ratings Characteristics 70 180° 60 120° 90° 50 ...
Page 6
IRK.41, .56 Series Bulletin I27131 rev. G 10/02 140 120 100 80 60 Conduction Angle Total RMS Output Current (A) Fig On-state Power Loss Characteristics 350 300 250 180° (Sine) 200 180° ...
Page 7
IRK.56.. Series R (DC) = 0.40 K/W thJC 120 110 Conduction Angle 100 90 30° 60° 90° 80 120° Average On-state Current (A) Fig Current Ratings Characteristics 90 180° 80 ...
Page 8
IRK.41, .56 Series Bulletin I27131 rev. G 10/02 200 180 160 140 120 100 80 Conduction Angle Total RMS Output Current (A) Fig On-state Power Loss Characteristics 450 400 350 ...
Page 9
T = 25° 125° IRK.41.. Series Per Junction Instantaneous On-state Voltage (V) Fig On-state Voltage Drop Characteristics 500 IRK.41.. Series IRK.56.. Series I = ...
Page 10
IRK.41, .56 Series Bulletin I27131 rev. G 10/02 100 Rectangular gate pulse a)Recommended load line for rated di/dt ohms tr = 0.5 µs, tp >= 6 µs b)Recommended load line for <= 30% rated di/dt ...
Page 11
WWW.ALLDATASHEET.COM Copyright © Each Manufacturing Company. All Datasheets cannot be modified without permission. This datasheet has been download from : www.AllDataSheet.com 100% Free DataSheet Search Site. Free Download. No Register. Fast Search System. www.AllDataSheet.com ...