V24C12C100BF2 Vicor Corporation, V24C12C100BF2 Datasheet - Page 6

no-image

V24C12C100BF2

Manufacturer Part Number
V24C12C100BF2
Description
Manufacturer
Vicor Corporation
Datasheet
Vicor Corp.
24 Vout, 50 W (e.g. V24C24C50BL)
28 Vout, 100 W (e.g. V24C28C100BL)
28 Vout, 50 W (e.g. V24C28C50BL)
36 Vout, 100 W (e.g. V24C36C100BL)
36 Vout, 50 W (e.g. V24C36C50BL)
Parameter
Efficiency
Ripple and noise
Output OVP setpoint
Dissipation, standby
Load regulation
Load current
Current limit
Short circuit current
Parameter
Efficiency
Ripple and noise
Output OVP setpoint
Dissipation, standby
Load regulation
Load current
Current limit
Short circuit current
Parameter
Efficiency
Ripple and noise
Output OVP setpoint
Dissipation, standby
Load regulation
Load current
Current limit
Short circuit current
Parameter
Efficiency
Ripple and noise
Output OVP setpoint
Dissipation, standby
Load regulation
Load current
Current limit
Short circuit current
Parameter
Efficiency
Ripple and noise
Output OVP setpoint
Dissipation, standby
Load regulation
Load current
Current limit
Short circuit current
MODULE SPECIFIC OPERATING SPECIFICATIONS (CONT.)
Tel: 800-735-6200, 978-470-2900 Fax: 978-475-6715
Set your site on VICOR at vicorpower.com
27.1
2.12
1.45
31.5
3.64
87.5
31.5
1.82
1.25
40.4
2.83
1.94
40.4
1.41
0.97
Min
Min
Min
Min
Min
0.5
87
88
86
84
0
0
0
0
0
±0.02
±0.02
±0.02
±0.02
±0.02
88.6
28.1
2.39
2.39
32.7
4.12
4.12
32.7
2.06
2.06
87.1
41.9
84.9
41.9
Typ
Typ
Typ
Typ
Typ
3.3
1.8
3.7
3.2
3.2
1.8
1.6
1.6
80
89
85
89
80
32
27
2
Max
29.1
±0.2
2.08
2.81
2.81
Max
33.9
±0.2
3.57
Max
33.9
±0.2
1.78
2.42
2.42
Max
43.4
±0.2
2.78
3.76
3.76
Max
43.4
±0.2
1.39
1.88
1.88
100
107
100
2.7
4.3
2.3
40
34
3
5
5
5
Watts
Amps
Amps
Amps
Watts
Amps
Amps
Amps
Watts
Amps
Amps
Amps
Watts
Amps
Amps
Amps
Watts
Amps
Amps
Amps
Volts
Volts
Volts
Volts
Volts
Unit
Unit
Unit
Unit
Unit
mV
mV
mV
mV
mV
%
%
%
%
%
%
%
%
%
%
24V Micro Family
Notes
Nominal input; full load; 25°C
p-p; Nominal input; full load; 20MHz bandwith
25°C; recycle input voltage to restart (>100 ms off)
No load
No load to full load; nominal input
Output voltage 95% of nominal
Output voltage < 250mV
Notes
Nominal input; full load; 25°C
p-p; Nominal input; full load; 20 MHz bandwith
25°C; recycle input voltage to restart (>100 ms off)
No load
No load to full load; nominal input
Output voltage 95% of nominal
Output voltage < 250 mV
Notes
Nominal input; full load; 25°C
p-p; Nominal input; full load; 20MHz bandwith
25°C; recycle input voltage to restart (>100 ms off)
No load
No load to full load; nominal input
Output voltage 95% of nominal
Output voltage < 250mV
Notes
Nominal input; full load; 25°C
p-p; Nominal input; full load; 20MHz bandwith
25°C; recycle input voltage to restart (>100 ms off)
No load
No load to full load; nominal input
Output voltage 95% of nominal
Output voltage <250 mV
Notes
Nominal input; full load; 25°C
p-p; Nominal input; full load; 20MHz bandwith
25°C; recycle input voltage to restart (>100 ms off)
No load
No load to full load; nominal input
Output voltage 95% of nominal
Output voltage <250 mV
Rev. 4.7
Page 6 of 13