Page 1
LH28F020SU-L FEATURES • 256K × 8 Bit Configuration • Write/Erase (3 • Access Time – For 3.3 V Read: 150 ns • Minimum 2.7 V Read Capability – 180 ns Maximum Access Time (V ...
Page 2
LH28F020SU-L OUTPUT MULTIPLEXER INPUT BUFFER Y-DECODER ADDRESS X-DECODER QUEUE LATCH ADDRESS COUNTER OUTPUT BUFFER ID QUEUE REGISTER REGISTER CSR DATA COMPARATOR Y GATING/SENSING . . . . . . ...
Page 3
... The flexible block locking option enables bundling of executable application software in a Resident Flash Array or memory card. Manufactured on Sharp’s 0.55 µm ETOX™ process technology, the LH28F020SU-L is the most cost-effective, high density 3.3 V flash memory. NAME AND FUNCTION BYTE-SELECT ADDRESSES : Select a byte within one 16K block ...
Page 4
LH28F020SU-L The LH28F020SU-L15 will be available in a 32-pin, 1.2 mm thick × TSOP (Type I) package. This form factor and pinout allow for very high board layout densities. A Command User Interface (CUI) serves as ...
Page 5
Flash Memory MEMORY MAP BUS OPERATIONS, COMMANDS AND STATUS REGISTER DEFINITIONS Bus Operations » » MODE CE OE Read Output Disable Standby Manufacturer ID V ...
Page 6
LH28F020SU-L LH28F008SA - Compatible Mode Command Bus Definitions COMMAND Read Array Intelligent Identifier Read Compatible Status Register Clear Status Register Byte Write Alternate Byte Write Block Erase/Confirm Erase Suspend/Resume ADDRESS DATA AA = Array Address AD = Array Data BA ...
Page 7
Flash Memory LH28F020SU-L Performance Enhancement Command Bus Definitions FIRST BUS CYCLE COMMAND OPER. Protect Set/Confirm Write Protect Reset/Confirm Write Lock Block/Confirm Write Erase All Unlocked Blocks Write Two-Byte Write Write ADDRESS DATA BA = Block Address ...
Page 8
... Set Write Protect command must be written to pro- hibit Write/Erase operations to each block. There are unassigned commands not recom- mended that the customer use any command other than the valid commands specified in “Command Bus Defi- nitions”. Sharp reserves the right to redefine these codes for future functions. ...
Page 9
Flash Memory START WRITE 40H or 10H WRITE DATA/ADDRESS READ COMPATIBLE STATUS REGISTER 0 CSR CSR FULL STATUS CHECK IF DESIRED OPERATION COMPLETE CSR FULL STATUS CHECK PROCEDURE READ CSRD (see above) 0 DATA ...
Page 10
LH28F020SU-L START WRITE 20H WRITE D0H AND BLOCK ADDRESS READ COMPATIBLE STATUS REGISTER NO 0 SUSPEND CSR.7 = ERASE 1 CSR FULL STATUS CHECK IF DESIRED OPERATION COMPLETE CSR FULL STATUS CHECK PROCEDURE READ CSRD (see above) 0 ERASE CSR.4, ...
Page 11
Flash Memory START WRITE B0H READ COMPATIBLE STATUS REGISTER 0 CSR CSR.6 = ERASE COMPLETED 1 WRITE FFH READ ARRAY DATA DONE NO READING YES WRITE D0H WRITE FFH ERASE RESUMED READ ARRAY ...
Page 12
LH28F020SU-L START READ COMPATIBLE STATUS REGISTER 0 CSR RESET WP READ COMPATIBLE STATUS REGISTER 0 CSR WRITE 77H WRITE D0H AND BLOCK ADDRESS READ COMPATIBLE STATUS REGISTER 0 CSR (NOTE) 1 CSR. ...
Page 13
Flash Memory START RESET WP (NOTE 1) ERASE BLOCK (NOTE 2) SET WP (NOTE 3) WRITE NEW DATA TO BLOCK (NOTE 4) RELOCK BLOCK (NOTE 5) OPERATION COMPLETE FLOW TO REWRITE DATA NOTES: 1. Use Reset-Write-Protect ...
Page 14
LH28F020SU-L START READ COMPATIBLE STATUS REGISTER 0 CSR WRITE FBH WRITE DATA/A 0 WRITE DATA/ADDRESS READ COMPATIBLE STATUS REGISTER 0 CSR (NOTE) 1 CSR. ANOTHER YES 2-BYTE WRITE NO OPERATION COMPLETE Figure 10. ...
Page 15
Flash Memory START (NOTE) WRITE A7H WRITE D0H READ COMPATIBLE STATUS REGISTER NO 0 SUSPEND CSR.7 = ERASE 1 CSR FULL STATUS CHECK IF DESIRED OPERATION COMPLETE CSR FULL STATUS CHECK PROCEDURE READ CSRD (see above) ...
Page 16
LH28F020SU-L START READ COMPATIBLE STATUS REGISTER 0 CSR WRITE 57H WRITE CONFIRM DATA/ADDRESS READ COMPATIBLE STATUS REGISTER 0 CSR (NOTE) CSR. OPERATION COMPLETE 16 BUS COMMAND OPERATION Read Write Set Write Protect ...
Page 17
Flash Memory START READ COMPATIBLE STATUS REGISTER 0 CSR WRITE 47H WRITE CONFIRM DATA/ADDRESS READ COMPATIBLE STATUS REGISTER 0 CSR (NOTE) CSR. OPERATION COMPLETE BUS COMMAND OPERATION Read ...
Page 18
LH28F020SU-L ELECTRICAL SPECIFICATIONS Absolute Maximum Ratings* Temperature Under Bias ....................... 0° 80°C Storage Temperature ........................ -65° 125°C SYMBOL PARAMETER T Operating Temperature, Commercial with Respect to GND Supply Voltage ...
Page 19
Flash Memory Timing Nomenclature For 3.3 V systems use 1.5 V cross point definitions. Each timing parameter consists of 5 characters. Some common examples are defined below time (t) from CE » ...
Page 20
LH28F020SU-L DC Characteristics V = 3.3 V ± 0 0°C to +70° SYMBOL PARAMETER I Input Load Current IL Output Leakage I LO Current I V Standby Current CCS Read Current ...
Page 21
Flash Memory DC Characteristics (Continued 3.3 V ± 0 0°C to +70° SYMBOL PARAMETER I V Read Current PPR Write Current PPW Erase ...
Page 22
LH28F020SU-L AC Characteristics - Read Only Operations V = 3.3 V ± 0 0°C to +70° SYMBOL PARAMETER t Read Cycle Time AVAV t Address Setup to OE » Going Low AVGL t Address to ...
Page 23
Flash Memory V CC POWER-UP STANDBY V IH ADDRESSES ( ( ( ( HIGH-Z DATA (D/Q) V ...
Page 24
LH28F020SU-L POWE R -UP AND RESET TIMINGS » V POWER (E) OE ( ADDRESS (A) DATA (Q) Figure 17. V SYMBOL PARAMETER t WE Low to V ...
Page 25
Flash Memory AC Characteristics for WE » - Controlled Command Write Operations V = 3.3 V ± 0 0°C to +70° SYMBOL PARAMETER t Write Cycle Time AVAV t ...
Page 26
LH28F020SU-L WRITE DATA-WRITE OR ERASE SETUP COMMAND V ADDRESSES (A) IH (NOTE AVAV ( WHEH t ELWL ( ( ...
Page 27
Flash Memory AC Characteristics for CE » - Controlled Command Write Operations V = 3.3 V ±0 0°C to +70° SYMBOL PARAMETER t Write Cycle Time AVAV » t ...
Page 28
LH28F020SU-L WRITE DATA-WRITE OR ERASE SETUP COMMAND V ADDRESSES (A) IH (NOTE AVAV ( EHWH t WLEL ( ( ...
Page 29
Flash Memory Erase and Byte Write Performance V = 3.3 V ± 0 0°C to +70° SYMBOL PARAMETER 1 t Byte Write Time WHRH 2 t Two-Byte Serial Write Time WHRH ...
Page 30
LH28F020SU-L 32TSOP (TSOP032-P-0820) 0.10 [0.004] M 0.30 [0.012] 0.50 [0.020] 0.10 [0.004] TYP 18.60 [0.732] 18.20 [0.717 8.20 [0.323] 7.80 [0.307] 0.15 [0.006] 0.425 [0.017] 0.10 [0.004] MAXIMUM LIMIT DIMENSIONS IN MM [INCHES] MINIMUM LIMIT ORDERING ...
Page 31
... Product which fails during the warranty period because of such defect (if Customer promptly reported the failure to SHARP in writing) or, (ii) if SHARP is unable to repair or replace, SHARP will refund the purchase price of the Product upon its return to SHARP . This warranty does not apply to any Product which has been subjected to misuse, abnormal service or handling, or which has been altered or modified in design or construction, or which has been serviced or repaired by anyone other than SHARP ...