V300B12T250BL Vicor Corporation, V300B12T250BL Datasheet
V300B12T250BL
Available stocks
Related parts for V300B12T250BL
V300B12T250BL Summary of contents
Page 1
... High frequency ZCS/ZVS switching provides high power density with low noise and high efficiency. Off-line systems with auto-ranging or PFC front ends, industrial and process control, distributed power, medical, ATE, communications, defense, aerospace e.g. V300B12T250BL2 V300B Output Voltage Product Grade Temperatures (°C) Grade Operating Storage ...
Page 2
Electrical characteristics apply over the full operating range of input voltage, output load (resistive) and baseplate temperature, unless otherwise specified. All temperatures refer to the operating temperature at the center of the baseplate. Operating input voltage 180 Input surge withstand ...
Page 3
Primary Control Parallel) PC bias voltage 5.50 current limit 1.5 PC module disable 2.3 PC module enable delay PC module alarm PR emitter amplitude 5.7 PR emitter current 150 PR receiver impedance 375 PR receiver threshold ...
Page 4
Efficiency 73 Ripple and noise Output OVP setpoint 2.7 Dissipation, standby Load regulation Load current 0 Current limit 51 Short circuit current 35 Efficiency 78 Ripple and noise Output OVP setpoint 4.14 Dissipation, standby Load regulation Load current 0 Current ...
Page 5
Efficiency 83.2 Ripple and noise Output OVP setpoint 9.36 Dissipation, standby Load regulation Load current 0 Current limit 25.5 Short circuit current 17.5 Efficiency 85.3 Ripple and noise Output OVP setpoint 13.7 Dissipation, standby Load regulation Load current 0 Current ...
Page 6
Efficiency 86.5 Ripple and noise Output OVP setpoint 27.1 Dissipation, standby Load regulation Load current 0 Current limit 10.7 Short circuit current 7.35 Efficiency 85.7 Ripple and noise Output OVP setpoint 27.1 Dissipation, standby Load regulation Load current 0 Current ...
Page 7
Efficiency 86.2 Ripple and noise Output OVP setpoint 40.4 Dissipation, standby Load regulation Load current 0 Current limit 4.25 Short circuit current 2.91 Efficiency 87.3 Ripple and noise Output OVP setpoint 53.7 Dissipation, standby Load regulation Load current 0 Current ...
Page 8
The module may be disabled by pulling PC below 2.3 V with respect to the –Input. This may be done with an open collector transistor, relay, or optocoupler. Multiple converters may be disabled with a single transistor or relay either ...
Page 9
The output voltage of the converter can be adjusted or programmed via fixed resistors, potentiometers or voltage DACs. See Figures 7 and 8. +Out +S Error SC Amp –S 1kΩ 0.033 μF –Out 1.23V 1,000 Vout R (ohms ...
Page 10
The PR pin supports paralleling for increased power with N+1 (N+M) redundancy and phased array capability. Modules of the same input voltage, output voltage, and power level will current share if all PR pins are suitably interfaced. Compatible interface architectures ...
Page 11
The +Out and –Out power buses +In +Out Module –S –S –In –Out • The +Sense pins should be tied +S +In +Out Module SC Load 2 PR –S –S ...
Page 12
No. Function Label 1 +In + Primary 2 PC Control 3 Parallel PR 0.23 (REF) 5,8 4 –In – 0.300 ±0.015 7,62 ±0,38 5 –Out – Pin –Sense –S 0.300 ±0.015 Secondary 7,62 ±0, Control ...
Page 13
Vicor products are guaranteed for two years from date of shipment against defects in material or workmanship when in normal use and service. This warranty does not extend to products subjected to misuse, accident, or improper application or maintenance. Vicor ...