V24A5T400AN Vicor Corporation, V24A5T400AN Datasheet
V24A5T400AN
Available stocks
Related parts for V24A5T400AN
V24A5T400AN Summary of contents
Page 1
RoHS Compliant (with pin option) DC input range: 18 – Input surge withstand for 100 ms DC output: 3.3 – Programmable output 110% Regulation: ±0.25% no load to full ...
Page 2
Electrical characteristics apply over the full operating range of input voltage, output load (resistive) and baseplate temperature, unless otherwise specified. All temperatures refer to the operating temperature at the center of the baseplate. Operating input voltage 18 Input surge withstand ...
Page 3
Primary Control Parallel) PC bias voltage 5.50 current limit 1.5 PC module disable 2.3 PC module enable delay PC module alarm PR emitter amplitude 5.7 PR emitter current 150 PR receiver impedance 375 PR receiver threshold ...
Page 4
Efficiency 75.5 Ripple and noise Output OVP setpoint 4.14 Dissipation, standby Load regulation Load current 0 Current limit 81.6 Short circuit current 56 Efficiency 73.9 Ripple and noise Output OVP setpoint 4.48 Dissipation, standby Load regulation Load current 0 Current ...
Page 5
Efficiency 85 Ripple and noise Output OVP setpoint 13.7 Dissipation, standby Load regulation Load current 0 Current limit 34 Short circuit current 23.3 Efficiency 86 Ripple and noise Output OVP setpoint 13.7 Dissipation, standby Load regulation Load current 0 Current ...
Page 6
Efficiency 86.8 Ripple and noise Output OVP setpoint 27.1 Dissipation, standby Load regulation Load current 0 Current limit 12.7 Short circuit current 8.75 Efficiency 86 Ripple and noise Output OVP setpoint 31.5 Dissipation, standby Load regulation Load current 0 Current ...
Page 7
Efficiency 84.7 Ripple and noise Output OVP setpoint 53.8 Dissipation, standby Load regulation Load current 0 Current limit 8.49 Short circuit current 4.79 Efficiency 86 Ripple and noise Output OVP setpoint 53.7 Dissipation, standby Load regulation Load current 0 Current ...
Page 8
The module may be disabled by pulling PC below 2.3 V with respect to the –Input. This may be done with an open collector transistor, relay, or optocoupler. Multiple converters may be disabled with a single transistor or relay either ...
Page 9
The output voltage of the converter can be adjusted or programmed via fixed resistors, potentiometers or voltage DACs. See Figures 7 and 8. +OUT +S Error SC Amp –S 0.033 μF 1 kΩ –OUT 1.23 V 1,000 Vout R (ohms) ...
Page 10
The PR pin supports paralleling for increased power with N+1 (N+M) redundancy and phased array capability. Modules of the same input voltage, output voltage, and power level will current share if all PR pins are suitably interfaced. Compatible interface architectures ...
Page 11
Module 1 SC –S –S –OUT +S +OUT +S +S Module 2 Load SC –S –S –OUT –S +OUT +S Module N+1 SC –S –OUT Figure 11 — N+1 module array output connections. (None) Short Tin/Lead L ...
Page 12
No. Function Label 1 +In + 0.300±0.015 7,62±0,38 Primary 2 PC 0.23 Control (REF) 5,8 3 Parallel PR Pin –In – 0.300±0.015 7,62±0,38 5 –Out – 6 –Sense –S Secondary 7 SC Control 8 +Sense +S 9 ...
Page 13
Vicor products are guaranteed for two years from date of shipment against defects in material or workmanship when in normal use and service. This warranty does not extend to products subjected to misuse, accident, or improper application or maintenance. Vicor ...