ZBZ1604 Crouzet USA, ZBZ1604 Datasheet - Page 150

17C8378

ZBZ1604

Manufacturer Part Number
ZBZ1604
Description
17C8378
Manufacturer
Crouzet USA
Datasheet

Specifications of ZBZ1604

Features
Red, Metal
Rohs Compliant
Yes
For Use With
40mm Emergency Stop And Mushroom Head Pushbuttons
In hazardous locations, it is not always required to use explosion-proof
equipment like the Class 9001 Type BR control stations. It can save
money to know what type of hazardous location exists. If you're not sure
what type of hazardous location exists, the “Summary of Classification”
Chart may help. If not, contact your local electrical inspector. When you
know what class, division, and group(s) exists, see the table in the lower
lefthand corner of this page for what Square D has to offer.
Summary Of Classification Chart
For
For ◆: Add Form Y243 to single lamp Push To Test pilot lights.
150
Push Buttons and Operator Interface - Type K and SK, 30 mm
Reed Contact Blocks & Hazardous Location Information - Type K, SK, KX, and T
I. Gas
II. Dust
III. Fibers
Class
An intrinsically safe system requires either a Class 8501 Type TO or NY2 barrier relay or an
intrinsically safe barrier to restrict the energy available in the area classified as a hazardous
area to a level less than that required to cause an explosion. In an intrinsically safe system,
any non-illuminated Class 9001 operator or control station with standard contacts can be
used. No illuminated operators, except the Class 9001 Type KP44 intrinsically safe pilot light,
may be used.
Any Class 9001 Type K, SK or KX operator can be used in an area classified as Class I, Divi-
sion 2 hazardous locations.
1. Only logic (KA40 series) or power (KA50 series) reed contact blocks are used.
2. All Type K and SK illuminated operators are UL approved for use in Class I Division 2
3. Type KX illuminated operators do not use 4 lamp light modules, or 2 lamp light modules
4. The operators are mounted in Type KY, KYSS, KYAF, SKY enclosures.
Any Class 9001 Type K, SK, or KX operator mounted in a Class 9001 Type KY, KYSS, KYAF,
SKY enclosure may be used, except potentiometer operators.
III
II
II
II
I
I
I
I
areas. ◆
other than the transformer type. ◆
and
© 1999-2005 Schneider Electric All Rights Reserved
Class
Division
: UL Listed: File E10054, CCN NOIV.
1, 2
1
1
2
2
1
2
2
For
Group(s)
1. Hazard May Exist
2. Potential Hazard
1. Hazard May Exist
2. Potential Hazard
1. Production Areas
2. Handling and Storage
B, C, D
B, C, D
E, F, G
E, F
May Exist In Atmosphere
Under Normal Operating
Conditions.
A. May be present in
B. Location adjacent to
May Exist In Atmosphere
Under Normal Operating
Conditions.
A. May be present in
Areas
G
A
A
atmosphere only
under abnormal
circumstances.
Division 1 location.
atmosphere only
under abnormal
circumstances.
Division
1. Intrinsically Safe System
1.
2.
1.
2.
1.
2.
3.
1.
2.
1.
2.
3.
1.
2.
3.
1.
2.
3.
9001 BR station
Intrinsically Safe System
9001 K, SK, KX control stations with the restrictions
listed in footnote
Intrinsically Safe System
9001 BR station
9001 K, SK, KX control stations with the restrictions
listed in footnote
Intrinsically Safe System
9001 BR station
Intrinsically Safe System
9001 BR station
9001 K, SK, KX control stations with the restrictions
listed in footnote
Intrinsically Safe System
9001 BR station
9001 K, SK, KX control stations with the restrictions
listed in footnote
Intrinsically Safe System
9001 BR Station
9001 K, SK, KX control stations with the restrictions
listed in footnote
Intrinsically Safe System
C. Petrochemicals (e.g. ethylene)
C. Petrochemicals (e.g. ethylene)
G. Non-Conductive Combustible Dust
G. Non-Conductive Combustible Dust
A. Acetylene
B. Hydrogen and Manufactured Gases
D. Petrochemicals (e.g. alcohol)
A. Acetylene
B. Hydrogen and Manufactured Gases
D. Petrochemicals (e.g. alcohol)
E. Conductive and Combustible Dust
F. Carbonaceous Dusts (Resistivity
containing Hydrogen
Containing Hydrogen
(Resistivity <10
>10
(Resistivity > = 10
(Resistivity > = 10
Easily Ignitable Fibers or Flyings
Easily Ignitable Fibers or Flyings
2
Use
ohm/cm but ð 10
Group
5
ohms/cm)
5
5
ohms/cm)
ohms/cm)
8
ohm/cm)
All contact blocks listed below will accept #12-18 solid or stranded wire.
Hermetically Sealed Logic Reed Contact Blocks
Suitable for use on low energy level circuits
The maximum number of logic and/or power reed contact blocks per opera-
tor is as indicated on page 155 for standard contact blocks,
except:
• On 3 position selector switches with cams “C,” “D,” “E,” “F,” “G,” “L,” or “M”
• On 4 position selector switches, mount reed blocks on one side only (ei-
Hermetically Sealed Power Reed Contact Blocks
The power reed contact blocks can be used with standard industrial relays and starters through
NEMA Size 4. Minimum voltage is 5 volts and the minimum current is 1 mA.
Pilot Light For Intrinsically Safe Circuits — NEMA / UL Type 4X
Inductive Rating – 35% Power Factor.
Inductive and Resistive Ratings.
On joysticks or on Type KR8 or SKR8 push-pull operators, mount reed blocks
mount reed blocks on one side only (either side), maximum 2 in tan-
dem.
ther side), maximum 2 in tandem.
on one side only (either side), maximum 2 in tandem
Volts
Volts
120
240
115
I max. = 165 mA
V max. = 32 V
Description
Description
Max. Volts AC/DC
120/100
Amps
Amps
32/30
10.00
0.50
5.00
Make
Make
ergy capable of igniting certain explosive or combustible hazardous at-
mosphere, for which the equipment has been tested.
a suitable approved barrier or barrier relay (Class 8501 Type TO or
NY2. These pilot lights are Factory Mutual FM# J.I. OH4A2,AX,3610
(FM approved). Consult your local Square D Sales Office for further de-
tails.
parts – except for the SK40 ring nut. Use KN100 series plastic legend
plates as shown on pages 152 and 153.
Intrinsically safe equipment must not release electrical or thermal en-
Listed below are pilot lights that are intrinsically safe when used with
These pilot lights are fully encapsulated – there are no replaceable
Operating
Voltage
20-30 V
Range
AC/DC
1200
1200
VA
VA
58
AC NEMA / UL Type C300
DC NEMA / UL Type Q150
Symbol
Symbol
Nominal
Current
0.25 A
Amps
Amps
25 mA
Res.
1.000
8 VA
0.500
0.50
Break
Break
Maximum Load
0.10 A
.
Green
Yellow
Color
3 VA
Lens
Ind.
120
120
Red
VA
VA
58
Type
KA41
KA42
KA43
KA44
KA45
Type
KA51
KA52
KA53
KA54
KA55
Continuous
Continuous
Carrying
Carrying
KP44R
KP44G
Amps
Amps
KP44Y
04/2005
Cont.
0.5 A
0.5 A
Type
3.0
3.0
3.0

Related parts for ZBZ1604