XPSMC16Z Crouzet USA, XPSMC16Z Datasheet - Page 90

34M0430

XPSMC16Z

Manufacturer Part Number
XPSMC16Z
Description
34M0430
Manufacturer
Crouzet USA
Datasheet

Specifications of XPSMC16Z

No. Of Digital Inputs
16
No. Of Digital Outputs
10
Rohs Compliant
Yes
Connections (continued)
K
F
Connections
XPSMF2DO801
XPSMF2DO1602
Item
Item
Connection
Programming
Safe Communication (all XPSMF Safety
PLCs and Remote I/Os)
Connection
Programming
Safe Communication (all XPSMF Safety
PLCs and Remote I/Os)
Type
Integrated 2 RJ45
switched Ethernet
Communication
ports
Type
Integrated 2 RJ45
switched Ethernet
Communication
ports
Function
Either of the two switched Ethernet ports can be used to create a connection between the safety
remote I/O and the programming terminal in a point to point or via an Ethernet network for setting the
IP address
Either of the two switched Ethernet ports can be used to create a connection between the safety
PLC and other safety related components (e.g other XPSMF safety PLCs or Safety Remote I/O
modules) this can be established in a point to point way or via an Ethernet network.
Function
Either of the two switched Ethernet ports can be used to create a connection between the safety
remote I/O and the programming terminal in a point to point or via an Ethernet network for setting the
IP address
Either of the two switched Ethernet ports can be used to create a connection between the safety
PLC and other safety related components (e.g other XPSMF safety PLCs or Safety Remote I/O
modules) this can be established in a point to point way or via an Ethernet network.
Safety automation system solutions
Preventa™ safety PLCs
Compact and modular
Safety remote output modules XPSMF2
A1
A2
B
C
D
E
F
G
H
J
A1
A2
B
C
D
E
Item
Item
Supply
Ground
Relay output 1
Relay output 2
Relay output 3
Relay output 4
Relay output 5
Relay output 6
Relay output 7
Relay output 8
Connection
Supply
Ground
Relay outputs 1 to 4
Relay outputs 5 to 8
Relay outputs 9 to 12
Relay outputs 13 to 16
Connection
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
Screw
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
Screw
L+
L+
L-
L-
t
Screw Function
L+
L+
L-
L-
t
Screw Function
Supply for relay outputs
Supply for relay outputs
Reference pole
Reference pole
Ground
Contact 1, terminal A
Contact 1, terminal B
Contact 2, terminal A
Contact 2, terminal B
Contact 3, terminal A
Contact 3, terminal B
Contact 4, terminal A
Contact 4, terminal B
Contact 5, terminal A
Contact 5, terminal B
Contact 6, terminal A
Contact 6, terminal B
Contact 7, terminal A
Contact 7, terminal B
Contact 8, terminal A
Contact 8, terminal B
Supply for relay outputs
Supply for relay outputs
Reference pole
Reference pole
Ground
Contact 1, terminal A
Contact 1, terminal B
Contact 2, terminal A
Contact 2, terminal B
Contact 3, terminal A
Contact 3, terminal B
Contact 4, terminal A
Contact 4, terminal B
Contact 5, terminal A
Contact 5, terminal B
Contact 6, terminal A
Contact 6, terminal B
Contact 7, terminal A
Contact 7, terminal B
Contact 8, terminal A
Contact 8, terminal B
Contact 9, terminal A
Contact 9, terminal B
Contact 10, terminal A
Contact 10, terminal B
Contact 11, terminal A
Contact 11, terminal B
Contact 12, terminal A
Contact 12, terminal B
Contact 13, terminal A
Contact 13, terminal B
Contact 14, terminal A
Contact 14, terminal B
Contact 15, terminal A
Contact 15, terminal B
Contact 16, terminal A
Contact 16, terminal B
2/89
10
10
1
1
2
2
3
3
4
4
5
5
6
6
7
7
8
8
9
9

Related parts for XPSMC16Z