XPSAV11113P Crouzet USA, XPSAV11113P Datasheet - Page 40

89H6663

XPSAV11113P

Manufacturer Part Number
XPSAV11113P
Description
89H6663
Manufacturer
Crouzet USA
Datasheet

Specifications of XPSAV11113P

Contact Voltage Dc Nom
24V
Relay Mounting
DIN Rail
External Height
66mm
External Width
114mm
External Depth
45mm
Rohs Compliant
Yes
Description
1
3
4
2
8
1
2
7
5
6
3 4
6
10
7
8
9
5
Safety automation system solutions
Preventa™ safety PLCs
Modular, XPSMF60
Rack, power supply and CPU
Modular assembly consisting of:
1 A metal rack XPSMFGEH01.
2 A c 24 V power supply module XPSMFPS01.
3 A central processing unit XPSMFCPU22.
4 Six optional “in rack” I/O cards (back plane bus assures the electrical connection
5 A metal plate for securing shielded analog input connection cables (EMC),
6 One ground connection screw.
7 Two cooling fans (beneath the metal rack).
8 Four Ø 0.55 in (14 mm) elongated holes for mounting the rack on a vertical
Power supply module XPSMFPS01 and Central processing unit XPSMFCPU22
consisting of:
1 Four voltage status LEDs (FAULT, 24 V, 3.3 V or 5 V).
2 A RESTART button (accessible using fine pointed tool).
3 A 3-pole terminal block (3 captive screws) for “Fault contact” function
4 A c 24 V supply terminal block, including ground connection
5 A grip to assist installation/removal of the power supply module.
6 Seven process status LEDs.
7 Four integrated RJ45 (type 10BASE-T/100BASE-TX) switched ports for
8 Two process status LEDs.
9 A SUB-D 9-pin connector (FB2) for connection on Modbus® serial (RTU) (FB1 not
10 A grip to assist installation/removal of the CPU.
(1) “Fault contact” function: the power supply module incorporates a volt-free changeover
contact. Operating errors occurring in the system are read and displayed by the LEDs. The errors
are analyzed on the programming PC:
(2) Removable screw terminal blocks are provided with the power supply and “in rack” I/O cards.
01
02
03 FAULT
Description
Modular safety PLC
of “in rack” cards installed, the power supply module and the CPU).
support.
Programming, and for Safety and non-safety related communication on Ethernet.
(safety related using SafeEthernet protocol and Non-safety related using
Modbus® TCP server protocol).
used), with process status LED.
Contact positions
1-2 closed (2-3 open)
1-2 open (2-3 closed)
Status
Normal operation of the PLC.
Absence of supply to the PLC or the CPU is in
ERROR STOP mode.
(2)
.
(1)
.
2/39
10
10
1
1
2
2
3
3
4
4
5
5
6
6
7
7
8
8
9
9

Related parts for XPSAV11113P