XPSAFL5130P Crouzet USA, XPSAFL5130P Datasheet - Page 200

89H6660

XPSAFL5130P

Manufacturer Part Number
XPSAFL5130P
Description
89H6660
Manufacturer
Crouzet USA
Datasheet

Specifications of XPSAFL5130P

Contact Current Max
30mA
Contact Voltage Dc Nom
24V
Contact Configuration
3PST-NO
Relay Mounting
DIN Rail
External Height
66mm
External Width
114mm
External Depth
22.5mm
Rohs Compliant
Yes
Wiring diagrams
Input A S21-S22
Input B S11-S22
Input S33-S34 (N.O.)
Output 13-14/23-24/33-34/
43-44/53-54/6364/73-74 (N.O.)
Output 81-82/91-92 (N.C.)
Output (K1 + K2) Y31/Y32
Output (Power) Y31/Y35
Output (input A) Y31/Y64
Output (input B) Y31/Y74
Key
Input A S21-S22
Input B S11-S22
Start button
S33-S34 (N.O.)
Output 13-14/23-24/33-34/
43-44/53-54/6364/73-74 (N.O.)
Output 81-82/91-92 (N.C.)
Output (K1 + K2) Y31/Y32
Output (Power) Y31/Y35
Output (input A) Y31/Y64
Link Y1-S37
Key
1
2
1 Supply voltage A1-A2, internal electronic fuse status
2 Input S22 (A)
3 Input S52 (B)
4 K1/K2 status (N.O. safety outputs closed)
Principle:
page 2/194
Output (input B) Y31/Y74
3
4
Functional diagrams of module XPSAR
Limit switch monitoring function with automatic start
Emergency stop monitoring or limit switch monitoring function with
monitored start
LED details
0
0
Supply
voltage
voltage
Supply
1
1
Start
activated
Starting
Characteristics:
page 2/194
deactivated
(continued)
Starting
Guard
opens
1
st
switch
t =
2
switch
nd
limit switch activated
Emergency stop or
Guard
opens
2
switch
nd
Safety automation system solutions
Preventa™ safety relay modules type XPSAR
For Emergency stop, switch or light curtain monitoring
References:
page 2/195
1
switch
st
Output (input B) Y31/Y74
Start button
S33-S34 (N.O.)
Output (input B) Y31/Y74
Input A S21-S22
Input B S11-S22
Input S33-S34 (N.O.)
Output 13-14/23-24/33-34/
43-44/53-54/6364/73-74 (N.O.)
Output 81-82/91-92 (N.C.)
Output (K1 + K2) Y31/Y32
Output (Power) Y31/Y35
Output (input A) Y31/Y64
Key
Input A S21-S22
Input B OSSD1 (ESPE)
- S52
Input OSSD2 (ESPE)
- S12
Output 13-14/23-24/33-34/
43-44/53-54/6364/73-74 (N.O.)
Output 81-82/91-92 (N.C.)
Output (K1 + K2) Y31/Y32
Output (Power) Y31/Y35
Output (input A) Y31/Y74
Link Y1-S37
Key
Limit switch monitoring function with automatic start and
synchronization time monitoring
Light curtain monitoring (ESPE) function, curtains with solid-state
outputs, and monitored start
0
0
0
0
Wiring Diagrams:
page 2/196
Supply
voltage
voltage
Supply
1
1
1
1
activated
Starting
Guard
opens
1
st
t
t
deactivated
switch
Starting
t
100 ms
100 ms
100 ms
2
switch
nd
Dimensions:
page 2/260
Light curtains
deactivated
Guard
opens
t
t
t
100 ms
100 ms
100 ms
2
switch
nd
Light curtains
activated
1
switch
st
2/199
10
10
1
1
2
2
3
3
4
4
5
5
6
6
7
7
8
8
9
9
0

Related parts for XPSAFL5130P