XPSAC5121P Crouzet USA, XPSAC5121P Datasheet - Page 114

89H6659

XPSAC5121P

Manufacturer Part Number
XPSAC5121P
Description
89H6659
Manufacturer
Crouzet USA
Datasheet

Specifications of XPSAC5121P

Contact Current Max
40mA
Contact Voltage Ac Nom
24V
Contact Voltage Dc Nom
24V
Contact Configuration
3PST-NO
Relay Mounting
DIN Rail
External Height
66mm
External Width
114mm
External Depth
22.5mm
Rohs Compliant
No
Wiring diagrams
Configuration 7 (2-channel Emergency stop, automatic or unmonitored start) = function 1.
Configuration 8 (2-channel Emergency stop, monitored start) = function 2.
(1) Automatic start.
(2) Function 1 safety outputs.
Configuration 7
Automatic start
Key
Input 1 C1-I1, (C4-I4)
Input 2 C2-I2, (C5-I5)
Automatic start C3-I3,
(C6-I6)
N.O. output 13-14/23-24/
33-34, (43-44/53-54/63-64)
Signalling output Y84,
(Y94)
Configuration 8
Monitored start
Key
Input 2 C2-I2, (C5-I5)
Start button C3-I3,
(C6-I6)
N.O. output 13-14/23-24/
33-34, (43-44/53-54/63-64)
Signalling output Y84,
(Y94)
Presentation:
page 2/106
Input 1 C1-I1, (C4-I4)
XPSMP
Emergency stop monitoring, 2-channel wiring
Functional diagrams
+
0 V
24 V
F1
0
0
A2
A1
C3
C6
1
1
No start-up (1)
C2
C5
Power-up (Self-test accomplished)
Power-up (Self-test accomplished)
Emergency stop
not activated
Emergency stop
not activated
C1
C4
Emergency
Emergency
Emergency
stop F1
Logic
channel 1
Logic
channel 2
Characteristics:
page 2/107
stop 1
stop 2
F2
F2
(continued)
S1
S4.1
S4.2
Emergency
stop
activated
Emergency
stop
activated
I1
I4
Function 1
Function 2
Function 1
Function 2
I2
I5
Emergency stop
not activated
Emergency stop
not activated
(F1)
(F2)
(F1)
(F2)
Start
F1
ESC
S3
F1
Start
K3
K4
K2
K11
K12
K1
Safety automation system solutions
Preventa™ safety controllers type XPSMP
With pre-defined functions
ESC
References:
page 2/108
F2
F2
K21
K22
I3
I6
S6
Function 1 Function 1
(1)
K11
13
14
(3) Function 2 safety outputs.
ESC = External start conditions.
Configuration 7
Unmonitored start
Input 1 C1-I1, (C4-I4)
Input 2 C2-I2, (C5-I5)
Start button C3-I3,
(C6-I6)
N.O. output 13-14/23-24/
33-34, (43-44/53-54/63-64)
Signalling output Y84,
(Y94)
(1) Start button control: the start button must not be activated on power-up.
Key
24
23
K12
(2)
0
33
34
Function 2 Function 2
Dimensions:
page 2/109
K21
1
43
44
Power-up (Self-test accomplished)
Emergency stop
not activated
53
54
K22
(3)
63
64
Y
+
Emergency
stop
activated
Y74
XPS MP
Wiring Diagrams:
page 2/110 to 2/117
Y84
Emergency stop
not activated
Y94
To PLC
2/113
10
10
1
1
2
2
3
3
4
4
5
5
6
6
7
7
8
8
9
9

Related parts for XPSAC5121P