184196-1 TE Connectivity, 184196-1 Datasheet - Page 3

Power to the Board HSG CAP 1X03C LOCK PLATE

184196-1

Manufacturer Part Number
184196-1
Description
Power to the Board HSG CAP 1X03C LOCK PLATE
Manufacturer
TE Connectivity
Datasheets

Specifications of 184196-1

Product Type
Accessories
Number Of Positions / Contacts
3
Accessory Type
Cap Lock Plate
Product Line
Sealed Sensor Connector (SSC)
Accessory Color
Yellow
Number Of Positions
3
Number Of Rows
1
Rohs/elv Compliance
ELV compliant
Lead Free Solder Processes
Not reviewed for lead free solder process
Rohs/elv Compliance History
Always was ELV compliant
Application Use
Wire-to-Wire / Wire-to-Panel
Packaging Method
Box
Packaging Quantity
3000
Lead Free Status / Rohs Status
 Details
For Use With
Cap Housing
Rev B
Disengaging force
(terminal-terminal).
Engaging force
(terminal-connector).
Engaging force
(terminal-connector).
Engaging force
(connector-connector).
Disengaging force
(connector-connector).
Locking plate (TPA) engaging
force.
Locking plate (TPA) disengaging
force.
Terminal bend resistance.
Thermal shock.
Test Description
2.5 Newtons minimum.
15 Newtons maximum.
40 Newtons minimum without TPA.
90 Newtons minimum with TPA.
90 Newtons maximum.
90 Newtons maximum with latch
disabled.
110 Newtons minimum with latch
operational.
No bend > than 30 degrees
permitted. Specimens shall not tear
when straightened to original
position.
See Note.
Position
3,4,6,12
Position
2,3
4,6
12
1
2
1
Figure 1 (continued)
ENVIRONMENTAL
Requirement
Minimum Maximum
Minimum Maximum
Newtons
Newtons
26
26
10
20
45
6
2
Newtons
Newtons
25
45
80
35
45
80
5
USCAR 5.2.1. (Rev 8/97)
Measure force necessary to
separate virgin contacts from tabs
at a rate of 25 mm per minute.
Repeat 9 times and record
minimum force.
USCAR 5.3.1. (Rev 8/97)
Measure force necessary to insert
contact into housing at a rate of 25
mm per minute.
USCAR 5.3.1. (Rev 8/97)
Measure force necessary to extract
contact from housing at a rate of 25
mm per minute.
USCAR 5.3.2. (Rev 8/97)
Measure force necessary to mate
specimens at a maximum rate of
25 mm per minute.
USCAR 5.3.2. (Rev 8/97)
Measure force necessary to
unmate 15 specimens with locking
latch operational, and 15
specimens with locking latch non-
operational at a maximum rate of
25 mm per minute.
USCAR 5.3.3. (Rev 8/97)
Measure force necessary to
engage the locking plate at a rate of
25 mm per minute.
USCAR 5.3.3. (Rev 8/97)
Measure force necessary to
disengage the locking plate at a
rate of 25 mm per minute.
USCAR 5.2.2. (Rev 8/97)
Crimp test wire and contact and
apply 12 Newtons force for 15
seconds.
See Figure 7.
USCAR 5.6.1. (Rev 4/01)
Subject mated specimens to 15
cycles between -40 and 125° C for
PBT housings and 150° C for nylon
housings. Two hour dwell at
temperature extremes.
Procedure
108-1790
3 of 9

Related parts for 184196-1