SI3018-F-GS Silicon Laboratories Inc, SI3018-F-GS Datasheet - Page 33

IC VOICE DAA GCI/PCM/SPI 16SOIC

SI3018-F-GS

Manufacturer Part Number
SI3018-F-GS
Description
IC VOICE DAA GCI/PCM/SPI 16SOIC
Manufacturer
Silicon Laboratories Inc
Type
Chipsetr
Datasheet

Specifications of SI3018-F-GS

Package / Case
16-SOIC (3.9mm Width)
Function
Data Access Arrangement (DAA)
Interface
Serial
Number Of Circuits
1
Voltage - Supply
3 V ~ 3.6 V
Current - Supply
8.5mA
Operating Temperature
-40°C ~ 85°C
Mounting Type
Surface Mount
Includes
Line Voltage Monitor, Loop Current Monitor, Overload Detection, Parallel Handset Detection, Polarity Reversal Detection, TIP and
Product
Modem Module
Supply Voltage (min)
3 V
Supply Current
15 mA
Maximum Operating Temperature
+ 70 C
Minimum Operating Temperature
0 C
Mounting Style
SMD/SMT
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Power (watts)
-
Lead Free Status / RoHS Status
Lead free / RoHS Compliant, Lead free / RoHS Compliant
Notes:
Command
1. When in autobaud mode, \B0, \B1, and \P1 will not be detected automatically. The combination of \B2 and \P3 will be
2. The autobaud feature does not detect this rate.
\Qn
\Q0
\Q2
\Bn
\B0
\B1
\B2
\B3
\B5
\B6
\Nn
\N0
\N2
\N3
\N4
\N5
\Pn
\P0
\P1
\P2
\P3
\$
detected. This is compatible with seven data bits, no parity, two stop bits. Seven data bits, no parity, one stop bit may be
forced by sending AT\T17\B1.
Display AT\ command settings.
Character length will be automatically set in autobaud mode
6N1—six data bits, no parity, one stop bit, one start bit, eight bits total (\N0 only)
7N1—seven data bits, no parity, one stop bit, one start bit, nine bits total (\N0 only)
7P1—seven data bits, parity optioned by \P, one stop bit, one start bit, 10 bits total
8N1—eight data bits, no parity, one stop bit, one start bit, 10 bits total
8P1—eight data bits, parity optioned by \P, one stop bit, one start bit, 11 bits total (\N0 only)
8X1—eight data bits, one escape bit, one stop bit, one start bit, 11 bits total (enables ninth-bit
escape mode)
Asynchronous protocol
Wire mode (no error correction, no compression)
MNP reliable mode. The Si2457/34/15/04 attempts to connect with the MNP protocol. If unsuccess-
ful, the call is dropped.
V.42 auto-reliable—The Si2457/34/15/04 attempts to connect with the V.42 protocol. If unsuc-
cessful, the MNP protocol is attempted. If unsuccessful, wire mode is attempted.
V.42 (LAPM) reliable mode (or drop call)—Same as \N3 except that the Si2457/34/15/04 drops the
call instead of connecting in MNP or wire mode.
V.42 and MNP reliable mode—The Si2457/34/15/04 attempts to connect with V.42. If unsuccessful,
MNP is attempted. If MNP us unsuccessful, the call is dropped.
Parity type will be automatically set in autobaud mode
Even
Space
Odd
Mark
Modem-to-DTE flow control
Disable all flow control—This may only be used if the DTE speed and the VF speed are guaranteed
to match throughout the call.
Use CTS only
Table 13. Extended AT\ Command Set (Command Defaults in Bold)
1
1
Rev. 1.1
Action
Si2457/34/15/04
1
1
33