ACPL-061L-000E Avago Technologies US Inc., ACPL-061L-000E Datasheet - Page 6

no-image

ACPL-061L-000E

Manufacturer Part Number
ACPL-061L-000E
Description
Manufacturer
Avago Technologies US Inc.
Datasheet

Specifications of ACPL-061L-000E

Number Of Elements
1
Input Type
DC
Output Type
Totem Pole
Forward Voltage
1.7V
Forward Current
8mA
Output Current
10mA
Isolation Voltage
3750Vrms
Operating Temp Range
-40C to 105C
Pin Count
8
Mounting
Surface Mount
Reverse Breakdown Voltage
5V
Operating Temperature Classification
Industrial
Lead Free Status / Rohs Status
Compliant

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
ACPL-061L-000E
Manufacturer:
AVAGO
Quantity:
2 001
IEC/EN/DIN EN 60747-5-5 Insulation Characteristics* (Option 060)
*
** Refer to the following figure for dependence of P
Absolute Maximum Ratings
6
Description
Installation classification per DIN VDE 0110/39, Table 1
Climatic Classification
Pollution Degree (DIN VDE 0110/39)
Maximum Working Insulation Voltage
Input to Output Test Voltage, Method b*
V
Partial discharge < 5 pC
Input to Output Test Voltage, Method a*
V
Partial discharge < 5 pC
Highest Allowable Overvoltage
(Transient Overvoltage t
Safety-limiting values
– maximum values allowed in the event of a failure.
Insulation Resistance at T
Parameter
Storage Temperature
Operating Temperature
Reverse Input Voltage
Supply Voltage
Average Forward Input Current
Peak Forward Input Current
(I
Output Current
Output Voltage
Input Power Dissipation
Output Power Dissipation
Lead Solder Temperature
Solder Reflow Temperature Profile
F
IORM
IORM
Refer to the optocoupler section of the Isolation and Control Components Designer’s Catalog, under Product Safety Regulations section, (IEC/EN/
DIN EN 60747-5-5) for a detailed description of Method a and Method b partial discharge test profiles.
at 1 Ps pulse width, <10% duty cycle)
for rated mains voltage ≤ 150 V
for rated mains voltage ≤ 300 V
for rated mains voltage ≤ 600 V
for rated mains voltage ≤ 1000 V
Case Temperature
Input Current**
Output Power**
x 1.875=V
x 1.6=V
PR
, Type and Sample Test, t
PR
, 100% Production Test with t
ini
S
, V
= 60 sec)
IO
= 500 V
rms
rms
rms
rms
m
= 10 sec,
Symbol
T
T
V
V
I
I
I
V
P
P
T
See Package Outline Drawings section
F
F(TRAN)
O
A
S
LS
R
DD
O
I
O
S
m
and I
=1 sec,
S
on ambient temperature.
Min
-55
-40
–0.5
Symbol
V
V
V
V
T
I
P
R
S, INPUT
S
S, OUTPUT
IORM
PR
PR
IOTM
S
Max
125
105
5
6.5
8
1
80
10
V
14
20
260°C for 10 sec., 1.6 mm below seating plane
DD
+0.5
ACPL-061L^/
ACPL-064L/
55/105/21
ACPL-M61L
1063
6000
I – IV
>10
I – III
I – II
560
896
150
150
600
2
9
Characteristic
Units
°C
°C
V
V
mA
A
mA
mA
V
mW
mW
ACPL-W61L/
55/105/21
ACPL-K64L
Condition
≤1 Ps Pulse Width,
<300 pulses per second
≤1 Ps Pulse Width,
<10% Duty Cycle
I – IV
I – IV
1140
2137
1824
8000
>10
I – III
I – III
175
230
600
2
9
Unit
V
V
V
V
°C
mA
mW
:
peak
peak
peak
peak

Related parts for ACPL-061L-000E