R1.188.0690.2 WIELAND ELECTRIC, R1.188.0690.2 Datasheet - Page 8

86K3706

R1.188.0690.2

Manufacturer Part Number
R1.188.0690.2
Description
86K3706
Manufacturer
WIELAND ELECTRIC
Datasheet

Specifications of R1.188.0690.2

Coil Voltage Vac Nom
24V
Coil Voltage Vdc Nom
24V
Contact Current Max
6A
Contact Voltage Ac Nom
230V
Contact Voltage Dc Nom
24V
No. Of Poles
4
Relay Mounting
DIN Rail
External Height
96.5mm
Rohs Compliant
Yes
Type
SNO4062K
SNO4062K
SNO4062K-A
SNO4062K-C
SNO4062KM
SNO4062KM
SNO4062KM-A
SNO4063K
SNO4063K-A
SNO4063KM
SNO4063KM-A
SNO5002K
SNT4M63K
SNT4M63K
SNT4M63K-A
SNV4063KL
SNV4063KL
SNV4063KL-A
SNV4063KL-C
SNV4063KP
SNV4063KP
SNV4063KP-A
SNV4074SL
SNV4074SL-A
SNV4074SL-C
SNV4074ST
SNV4074ST
SNV4076SL
SNV4076SL
SNV4076SL-A
SNV4076SL-C
SNV4274SL
SNV4274SL
SNZ4052K
SNZ4052K
SNZ4052K-A
SNZ4052K-C
Brief description
Base device
– single-channel or two-channel activation – automatic and
manual Reset with Reset button monitoring – short-circuit
detection – 2 enables – 1 indicator
Base device like SNO 4062K
– specially for light curtains and short-circuit forming
Base device
– single-channel or two-channel activation
– automatic and manual Reset
– with Reset button monitoring
– cross monitoring
– 3 enables
Base device like SNO 4063K – specially for light curtains and
short-circuit forming safety mats (4-wire technology)
Base device
– single-channel activation in the supply circuit
– automatic and manual Reset with Reset button monitoring
– 2 enables – 1 indicator
– safe isolation of control and output circuit
Protective door monitor
– two-channel activation – activation NC/NO or NC/NC
– synchrocheck
– automatic and manual Reset
– with Reset button monitoring – 3 enables
Base device
– single-channel or two-channel activation through contacts
– automatic and manual Reset
– with Reset button monitoring – 2 immediate enables
– 1 enable OFF-delayed
Base device
– single-channel or two-channel activation through contacts
– with Reset button monitoring – 2 immediate enables
– 1 enable ON-delayed
Base device
– single-channel or two-channel activation through contacts
– automatic and manual Reset, with Reset button monitoring
– 2 immediate enables
– 2 enables OFF-delayed without re-triggering
– 2 signaling contacts with immediate response
– 2 signaling contacts delayed
Safe timer relay
– ON-delay
– automatic and manual Reset – with Reset button monitoring
– 2 NO with immediate response – 2 NO ON-delayed,
– 2 NC with immediate response – 2 NC ON-delayed
Base device
– single-channel or two-channel activation through contacts
– automatic and manual Reset
– with Reset button monitoring
– 3 immediate enables
– 3 enables OFF-delayed, without re-triggering
– 1 signaling contact with immediate response
Safe timer relay
– OFF delay with re-triggering
– automatic and manual Reset
– with Reset button monitoring
– 2 NO with immediate response – 2 NO OFF-delayed
– 2 NC with immediate response – 2 NC OFF-delayed
Base device
– two-channel activation; 2x NC/NO start inhibit
– cross monitoring
– synchronous time monitoring
– 2 enables
– 1 indicator
safety mats (4-wire technology)
or semiconductors
or semiconductors – automatic and manual Reset
or semiconductors
or semiconductors
Additional items with plug-in terminals for screw or spring clamp available upon request
Terminals
Screw terminals, fi xed
Plug-in screw terminals
Plug-in spring clamp terminals
Screw terminals, fi xed
Plug-in screw terminals
Screw terminals, fi xed
Plug-in screw terminals
Screw terminals, fi xed
Plug-in screw terminals
Screw terminals, fi xed
Screw terminals, fi xed
Plug-in screw terminals
Screw terminals, fi xed
Plug-in screw terminals
Plug-in spring clamp terminals
Screw terminals, fi xed
Plug-in screw terminals
Screw terminals, fi xed
Plug-in screw terminals
Plug-in spring clamp terminals
Screw terminals, fi xed
Plug-in screw terminals
Plug-in screw terminals
Plug-in spring clamp terminals
Screw terminals, fi xed
Screw terminals, fi xed
Plug-in screw terminals
Plug-in spring clamp terminals
Rated voltage
AC/DC 24 V, 50-60Hz
AC/DC 24 V, 50-60Hz
AC/DC 24 V, 50-60Hz
AC/DC 24 V, 50-60Hz
AC/DC 24 V, 50-60Hz
AC/DC 24 V, 50-60Hz
DC 12 V
AC 115-120 V, 50-60Hz
AC 230 V, 50-60Hz
AC/DC 24 V, 50-60Hz
AC/DC 24 V, 50-60Hz
AC/DC 24 V, 50-60Hz
DC 12 V
DC 24 V
AC 115-120 V, 50-60Hz
AC 230 V, 50-60 Hz
AC/DC 24 V, 50-60Hz
AC 115-120 V, 50-60Hz
AC 230 V, 50-60Hz
AC/DC 24 V, 50-60Hz
DC 24 V
DC 24 V
DC 24 V
DC 24 V
DC 24 V
DC 24 V
DC 24 V
DC 24 V
DC 24 V
DC 24 V
AC 115-230 V 50-60Hz 0 - 3s
DC 24 V
AC 115-230 V 50-60Hz 0.3 - 3s
DC 24 V
AC 115-230 V 50-60Hz 0 - 3s
DC 24 V
AC 115-230 V 50-60Hz 0.3 - 3s
AC/DC 24 V 50-60Hz
AC 115-120 V 50-60Hz
AC 230 V 50-60Hz
AC/DC 24 V 50-60Hz
AC/DC 24 V 50-60Hz
Specifi -
cation
0.15 - 3s
1.5 - 30s
0.15 - 3s
1.5 - 30s
0.15 - 3s
0.15 - 3s
1.5 - 30s
0.15 - 3s
1.5 - 30s
0 - 3s
0 - 30s
0 - 300s
0 - 30s
0 - 300s
0 - 3s
0 - 3s
0 - 30s
0 - 300s
0 - 3s
0 - 30s
0 - 300s
0 - 30s
0 - 300s
0 - 3s
0 - 3s
0 - 30s
0 - 300s
Part number
R1.188.0690.2
R1.188.0700.2
R1.188.2000.0
R1.188.0710.2
R1.188.0720.2
R1.188.0960.0
R1.188.1110.0
R1.188.0970.0
R1.188.0980.0
R1.188.0990.0
R1.188.1270.0
R1.188.1280.0
R1.188.1650.0
R1.188.1360.0
R1.188.1370.0
R1.188.1350.0
R1.188.1020.0
R1.188.1030.0
R1.188.1040.0
R1.188.1050.0
R1.188.0610.0
R1.188.0630.0
R1.188.0620.0
R1.188.0640.0
R1.188.2010.0
R1.188.0650.0
R1.188.0670.0
R1.188.0660.0
R1.188.0680.0
R1.180.2120.0
R1.180.2150.0
R1.180.2180.0
R1.180.2300.0
R1.180.2330.0
R1.180.2360.0
R1.180.2130.0
R1.188.2140.0
R1.188.2730.0
R1.188.2760.0
R1.188.2790.0
R1.180.2030.0
R1.180.2060.0
R1.180.2090.0
R1.180.2210.0
R1.180.2240.0
R1.180.2270.0
R1.180.2040.0
R1.188.2150.0
R1.188.2640.0
R1.188.2670.0
R1.188.2700.0
R1.188.0450.1
R1.188.0920.1
R1.188.0930.1
R1.188.0530.1
R1.188.2020.0