HR2S-332N-T15 IDEC, HR2S-332N-T15 Datasheet - Page 2

47T1446

HR2S-332N-T15

Manufacturer Part Number
HR2S-332N-T15
Description
47T1446
Manufacturer
IDEC
Datasheet
HR2S
Safety Relay Modules
SAFETY
HR2S-301P
Auxiliary output (NC) can be used for monitoring.
Compliant with categories 2 and 3 when
used with a safety switch.
Compliant with categories 2 (type 2) and
4 (type 4) when used with a safety light curtain.
3NO and 1NC output contacts
Complies with international standards
Safety Category 4, Performance
Level e according to
EN ISO 13849-1: 2008
TÜV SÜD
European and North American (NRTL)
Slim safety relay module with spring
terminals enables easy wiring!
HR2S-301N
Auxiliary output (NC) can be used for monitoring.
HR2S-301P
3NO and 1NC output contacts
Compliant with Category 4
SIMPLE
COMPACT
Removable terminal block
enables easy replacement
The terminals can be attached and
removed easily with a flat screwdriver
allowing easy replacement of the
module.
1
The terminal cover detects
improper connection
The terminal cover does not close if
the terminal is not fully inserted into
the module.
Operation modes can
be changed with a
single action
The switch on the front panel
allows switching between Auto
and Manual modes.
Insert
1
No tools needed.
Directly insert a
ferrule into the terminal.
The wire is locked.
HR2S-301P
HR2S-301N
Simple wiring procedure
· HR2S-332N-T075=0.5/1/1.5/2/2.5/3/3.5/4/4.5/5/5.5/6/6.5/7/7.5s
· HR2S-332N-T15=1/2/3/4/5/6/7/8/9/10/11/12/13/14/15s
· HR2S-332N-T30=2/4/6/8/10/12/14/16/18/20/22/24/26/28/30s
No complex work required. Just insert a ferrule
into the terminal. The wire is locked into the
spring terminal so a screwdriver is not required
when inserting the wire.
HR2S-332NT-
075/15/30
Compact design enables
installation in a narrow space
Time-delay output
Time setting can be selected from
3NO (time-delay safety output)
compliant with category 4
3NO (safety output) and
31 different time ranges
Removal
Time-delay output
1
1
HR2S-332NT
Insert a flat
screwdriver
into the terminal
entrance.
2
2
Not fully inserted
(110127)
Remove the
wire by releasing
the lock with a
screwdriver.

Related parts for HR2S-332N-T15