G6K2FDC24 Omron, G6K2FDC24 Datasheet - Page 8

G6K2FDC24

Manufacturer Part Number
G6K2FDC24
Description
Manufacturer
Omron
Type
Signal Relayr
Datasheet

Specifications of G6K2FDC24

Relay Construction
Non-Latching
Contact Arrangement
DPDT
Coil Voltage Dc
24V
Coil Current
4.6mA
Contact Form
2 Form C
Voltage Rating (vdc)
60V
Voltage Rating (vac)
125V
Dropout Volt (min)
2.4VDCV
Coil Resistance
5.22kohm
Pick-up Voltage (max)
19.2VDC
Maximum Power Rating
30W/37.5VA
Operate Time
3ms
Contact Current Rating
1A
Contact Material
Ag/Au
Coil Suppression Diode
No
Push To Test Button
No
Led Indicator
No
Seal
Unsealed
Product Height (mm)
5.2mm
Product Depth (mm)
7.8mm
Product Length (mm)
10mm
Operating Temp Range
-40C to 70C
Pin Count
8
Mounting Style
Surface Mount
Termination Style
Gull Wing
Lead Free Status / Rohs Status
Compliant
■ Recommended Soldering Method
Temperature indicates the surface temperature of the PCBs.
IRS Method (for surface mounting terminal models)
(1) IRS Method (Mounting Solder: Lead)
• The thickness of cream solder to be applied should be within a range between 150 and 200 μm on OMRON’s recommended PCB pattern.
• In order to perform correct soldering, it is recommended that the correct soldering conditions be maintained as shown below on the left side.
Visually check that the Relay is properly soldered.
Precautions
■ Correct Use
Handling
Do not unpack the relay until mounting it.
Soldering
Solder: JIS Z3282, H63A or equivalent
Soldering temperature: Approx. 250°C (260°C if the DWS method is
used)
Soldering time: Approx. 5 s max. (approx. 2 s for the first time and
approx. 3 s for the second time if the DWS method is used)
Be sure to make a molten solder level adjustment so that the solder
will not overflow on the PCB.
Claw Securing Force During Automatic
Mounting
During automatic insertion of Relays, make sure to set the securing
force of each claw to the following so that the Relays characteristics
will be maintained.
74
PCB
Correct Soldering
220 to
180 to
245
200
150
Terminal
Low Signal Relay
Relay
Solder
Land
Preheating
90 to 120
Direction A: 1.96 N
Direction B: 4.90 N
Direction C: 1.96 N
Incorrect Soldering
Soldering
20 to 30
Insufficient
amount of
solder
G6K
Time (s)
Excessive
amount of
solder
(2) IRS Method (Mounting Solder: Lead-free)
Environmental Conditions During Operation,
Storage, and Transportation
It is best to keep the relay in its packaging in a controlled environ-
ment until it is ready for mounting.
If the Relay is stored for a long time in an adverse environment with
high temperature, high humidity, organic gases, or sulfide gases, sul-
fide or oxide films will form on the contact surfaces. These films may
result in unstable contact, contact problems, or functional problems.
Therefore, operate, store, or transport the product under specified
environmental conditions.
Latching Relay Mounting
Make sure that the vibration or shock that is generated from other
devices, such as relays in operation, on the same panel and imposed
on the Latching Relay does not exceed the rated value, otherwise the
Latching Relay that has been set may be reset or vice versa. The
Latching Relay is reset before shipping. If excessive vibration or
shock is imposed, however, the Latching Relay may be set acciden-
tally. Be sure to apply a reset signal before use.
Maximum Allowable Voltage
The maximum allowable voltage of the coil can be obtained from the
coil temperature increase and the heat-resisting temperature of coil
insulating sheath material. (Exceeding the heat-resisting tempera-
ture may result in burning or short-circuiting.) The maximum allow-
able voltage also involves important restrictions which include the
following:
Note: The temperature profile indicates the
250 max.
230
180
150
temperature of the relay terminal
section.
Upper surface of case (peak):
255˚C max.
120 max.
Preheating
30 max.
Soldering
Relay
terminal
section
Time (s)

Related parts for G6K2FDC24