HMC1043-TR Honeywell, HMC1043-TR Datasheet - Page 6

no-image

HMC1043-TR

Manufacturer Part Number
HMC1043-TR
Description
Manufacturer
Honeywell
Datasheet

Specifications of HMC1043-TR

Lead Free Status / Rohs Status
Not Compliant
Honeywell
12001 Highway 55
Plymouth, MN 55441
Tel: 800-323-8295
www.honeywell.com/magneticsensors
HMC1043
A reset pulse is defined as a negative pulse current entering the S/R+ strap connection. The successful result would be
the magnetic domains aligned in a reverse easy-axis direction so that sensor bridge’s polarity is a negative slope with
positive fields on the sensitive axis result in negative voltages across the bridge output connections.
Typically a reset pulse is sent first, followed by a set pulse a few milliseconds later. By shoving the magnetic domains in
completely opposite directions, any prior magnetic disturbances are likely to be completely erased by the duet of pulses.
For simpler circuits with less critical requirements for noise and accuracy, a single polarity pulse circuit may be employed
(all sets or all resets). With these uni-polar pulses, several pulses together become close in performance to a set/reset
pulse circuit. Figure 1 shows a quick and dirty manual pulse circuit for uni-polar application of pulses to the set/reset strap.
ORDERING INFORMATION
FIND OUT MORE
For more information on Honeywell’s Magnetic Sensors visit us online at www.magneticsensors.com or contact us at
800-323-8295 (763-954-2474 internationally).
The application circuits herein constitute typical usage and interface of Honeywell product. Honeywell does not warranty or assume liability of customer-
designed circuits derived from this description or depiction.
Honeywell reserves the right to make changes to improve reliability, function or design. Honeywell does not assume any liability arising out of the
application or use of any product or circuit described herein; neither does it convey any license under its patent rights nor the rights of others.
U.S. Patents 4,441,072, 4,533,872, 4,569,742, 4,681,812, 4,847,584 6,529,114 and 7,095,226 apply to the technology des cribed
6
Ordering Number
HMC1043
HMC1043-TR
HMC1043-demo
5 volts
5 volts
Product
Cut Tape
Tape and Reel with 1k units /reel
Demonstration Board
Manual Set Pulse Circuit
Form #900341 Rev E
February 2009
©2009 Honeywell International Inc.
Figure 1
Iset
Iset
Rsr
Rsr
3.0
3.0
www.honeywell.com

Related parts for HMC1043-TR