ADM2687EBRIZ Analog Devices Inc, ADM2687EBRIZ Datasheet - Page 5

no-image

ADM2687EBRIZ

Manufacturer Part Number
ADM2687EBRIZ
Description
58T8846
Manufacturer
Analog Devices Inc
Datasheet

Specifications of ADM2687EBRIZ

No. Of Channels
1
Propagation Delay
100ns
Supply Current
72mA
Supply Voltage Range
3V To 5.5V
Digital Ic Case Style
SOIC
No. Of Pins
16
Operating Temperature Range
-40°C To +85°C
Rohs Compliant
Yes

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
ADM2687EBRIZ
Manufacturer:
ADI/亚德诺
Quantity:
20 000
Part Number:
ADM2687EBRIZ-RL7
Manufacturer:
ST
Quantity:
201
Part Number:
ADM2687EBRIZ-RL7
Manufacturer:
ADI/亚德诺
Quantity:
20 000
REGULATORY INFORMATION
Table 5. ADM2682E/ADM2687E Approvals (Pending)
Organization
UL (Pending)
CSA (Pending)
VDE (Pending)
INSULATION AND SAFETY-RELATED SPECIFICATIONS
Table 6.
Parameter
Rated Dielectric Insulation Voltage
Minimum External Air Gap (Clearance)
Minimum External Tracking (Creepage)
Minimum Internal Gap (Internal Clearance)
Tracking Resistance (Comparative Tracking Index)
Isolation Group
Approval Type
To be recognized under the UL 1577 Component Recognition Program of Underwriters Laboratories, Inc.
Single protection, 5000 V rms isolation voltage.
In accordance with UL 1577, each
≥ 6000 V rms for 1 second.
To be approved under CSA Component Acceptance Notice #5A.
Reinforced insulation per IEC 60601-1, 250 V rms (353 V peak) maximum working voltage.
Basic insulation per IEC 60601-1, 400 V rms (566 V peak) maximum working voltage.
Reinforced insulation per CSA 60950-1-07 and IEC 60950-1, 380 V rms (537 V peak) maximum working voltage.
Basic insulation per CSA 60950-1-07 and IEC 60950-1, 600 V rms (848 V peak) maximum working voltage.
To be certified according to DIN EN 60747-5-2 (VDE 0884 Part 2):2003-01.
In accordance with DIN EN 60747-5-2, each
≥1590 V peak for 1 second.
ADM2682E/ADM2687E
Symbol
L(I01)
L(I02)
CTI
Rev. 0 | Page 5 of 24
ADM2682E/ADM2687E
Value
5000
>8.0
>8.0
0.017 min
>175
IIIa
is proof tested by applying an insulation test voltage
Unit
V rms
mm
mm
mm
V
is proof tested by applying an insulation test voltage
Test Conditions/Comments
1-minute duration
Measured from input terminals to output terminals,
shortest distance through air
Measured from input terminals to output terminals,
shortest distance along body
Insulation distance through insulation
DIN IEC 112/VDE 0303-1
Material Group (DIN VDE 0110:1989-01, Table 1)
ADM2682E/ADM2687E