G6E134PSTUSDC3

Manufacturer Part Number
G6E134PSTUSDC3
Description
Manufacturer
Omron
Type
Signal Relayr
Datasheet

Specifications of G6E134PSTUSDC3

Relay Construction
Non-Latching
Contact Arrangement
SPDT
Coil Voltage Dc
3V
Coil Current
66.7mA
Contact Form
1 Form C
Voltage Rating (vdc)
220V
Voltage Rating (vac)
250V
Dropout Volt (min)
0.3VDCV
Coil Resistance
45Ohm
Pick-up Voltage (max)
2.1VDC
Maximum Power Rating
60W/50VA
Operate Time
5ms
Contact Current Rating
3A
Contact Material
Ag/Au Clad
Coil Suppression Diode
No
Push To Test Button
No
Led Indicator
No
Seal
Sealed
Product Height (mm)
8.38mm
Product Depth (mm)
9.91mm
Product Length (mm)
16mm
Operating Temp Range
-40C to 70C
Pin Count
5
Mounting Style
Through Hole
Termination Style
PC Pin
Lead Free Status / Rohs Status
Compliant
Precautions
■ Precautions for Correct Use
Long-term Continuously ON Contacts
Using the Relay in a circuit where the Relay will be ON continuously
for long periods (without switching) can lead to unstable contacts
because the heat generated by the coil itself will affect the insulation,
causing a film to develop on the contact surfaces. We recommend
using a latching relay (magnetic-holding relay) in this kind of circuit. If
a single-side stable model must be used in this kind of circuit, we rec-
ommend using a fail-safe circuit design that provides protection
against contact failure or coil burnout.
Installation
Do not reverse the polarity of the coil (+, -).
Provide sufficient space between Relays when mounting two or more
on the same PCB, as shown in the following diagram.
■ Hints on Correct Use
Single-winding type (G6EU)
Example of low-power consumption driver circuit
1. This is an example of a driver circuit that allows Model G6E to
2. The relay is set by an abrupt current charged to capacity C. This
3. The relay is reset by the discharge current of C flowing in the relay
Note: 1. Give adequate consideration to the circuit constant when
94
function as a normal relay with a normal switching pulse input.
current flows in the relay via diode D
via transistor TR and C.
2. OMRON owns the patent on this circuit. Consult OMRON
actually using this circuit, confirming the set and reset status
of the relay.
when using this circuit.
Low Signal Relay
Close
mounting
Distance between terminals:
2.54 × 2 (pitch) max.
G6E
1
and C and out via diode D
2
.
Wiring
Refer to the following diagram when wiring to switch a DC load. The
difference in polarity applied to the contacts will affect the endurance
of the Relay due to the amount of contact movement. To extend the
endurance characteristics beyond the performance ratings, wire the
common (pin 7) terminal to the positive (+) side.
Ultrasonic Cleaning
Do not use ultrasonic cleaning on standard relay models. Doing so
may result in resonance, coil burnout, and contact adhesion within
the Relay.
Relay Handling
When washing the product after soldering the Relay to a PCB, use a
water-based solvent or alcohol-based solvent, and keep the solvent
temperature to less than 40°C. Do not put the Relay in a cold clean-
ing bath immediately after soldering.
+
Wiring Diagram
Load
12
7
10
Load

Related parts for G6E134PSTUSDC3