ATV212WU55N4 SQUARE D, ATV212WU55N4 Datasheet - Page 4

no-image

ATV212WU55N4

Manufacturer Part Number
ATV212WU55N4
Description
52T3467
Manufacturer
SQUARE D
Datasheet

Specifications of ATV212WU55N4

Supply Voltage Range
380VAC To 480VAC
No. Of Phases
3
Power Rating
5.5kW
Rohs Compliant
Yes
Output Current
12A
Altivar 212 Drive Technical Characteristics
4
Environmental Specifications
Temperature ratings
Altitude ratings
Humidity
Vibration resistance
Shock resistance
Pollution degree
Degree of protection: ATV212 H range
ATV212 W range
Electrical Specifications
Input voltage and HP range ATV212 W
is available in 380/480 range only
Input frequency
Galvanic isolation
Drive input power section
Drive output power section
Power factor
Efficiency
Switching frequency
Acceleration and deceleration ramps
Frequency output range
Skip frequencies
Speed range
Integrated motor protection
Asynchronous motor control profiles
Transient over current
Embedded functions
User interface
Embedded communication
Harmonic abatement
EMC compliance: ATV212 H and W N4 range:
A TV212 W N4C range:
A TV212H M3X range:
Compliance
Certifications
0 to + 40°C operational without de-rating, up to 60°C with de-rating (see installation manual
for deratings)
Up to 3,300 ft (1,000 meters) without de-rating, de-rate nominal current by 1% for each additional 330 ft
( 100m) up to 10,000 ft ( 3,000 m)
Limit to 6,600 ft (2,000 m) if supplied by corner grounded distribution system
Up to 95% non-condensing , IEC 60068-2-3
1.5 mm peak to peak from 3 to 13 Hz conforming to EN/IEC 600068-2-6, 1 gn from 13 to 200 Hz
conforming to IEC/EN 60068-2-8
15 gn for 11 ms conforming to IEC/EN 60068-2-27
1 HP to 25 HP @ 200/240 V, 1 HP to 5 HP @ 380/480 V: Pollution degree 2 per IEC/EN 61800-5-1, 30
HP to 40 HP @ 200/240 V, 30 HP to 100 HP @ 380/480 V: Pollution degree 3 per IEC/EN 61800-5-1
IP20, Conformal coating per IEC 60721-3-3 classes 3C2 and 3S2, Type 1 with optional conduit kit
IP54/Type 12, Conformal coating per IEC 60721-3-3 classes 3C2 and 3S2
200 – 15% to 240 +10%, Three phase input, Three phase output, 1 HP to 40 HP
380 – 15% to 480 +10%, Three phase input, Three phase output, 1 HP to 100 HP
50 Hz -5% to 60 Hz +5%
Galvanic isolation between power and control (inputs, outputs and power supplies)
Six pulse bridge rectifier
IGBT inverter with pulse width modulated output
Above 99%
Above 98% at full load
Selectable from 6 to 16 kHz, 12 kHz nominal rating for 1 HP to 20 HP @ 200/240 V, 380/480 V
Selectable: 6 to 16 kHz, 8kHz nominal rating for 30 HP to 40 HP @ 200/240 V, 30 HP to
100 HP @ 380/480 V
0.1 to 3200 seconds in 0.1 seconds increments
0.5 to 200 hertz
Three adjustable skip frequency bands
1 to 10
Class 10 electronic overload protection
Sensorless flux vector, 2 point volts/hertz, quadratic volts/hertz, energy savings mode: a optimization
motor algorithm that automatically optimizes voltage based on load
110% nominal for 60 seconds, 180% for 2 seconds
Over 50 functions dedicated to pump and fan applications
On board: 5 LED indicators for various functions, 4 digit, 7 segment LED display with 7 button keypad
for: Run, Stop/Reset, Local/remote, Speed up, speed down, Mode selection and Enter. Quick start
menu, fault history, I/O mapping, last-used menus, status monitoring and self diagnostics. Fault
messages and status such as: power on time, elapsed time, motor run time, line voltage, motor
current, ready to run, running, motor speed, etc.
Embedded RJ45 port for remote keypad connection, Multi-loader, PC software, or Bluetooth dongle
for So Mobile smart phone connection. Embedded 4 screw removable terminal for daisy chain
connection for: Modbus, BACnet, Metesys N2, or Apogee P1 communication networks.
Embedded reduced harmonic technology provides <35% THDI at VFD input terminals,
which is equivalent to a 3% line reactor or DC choke. See technical paper 8800DB0702
for more information.
Integrated Class 2 EMC filter for radiated and conducted emissions, IEC 61800-3, category C2 and C3
Integrated Class 2 EMC filter for radiated and conducted emissions, IEC 61800-3, category C1
No integrated EMC filter (use optional filters to reduce emission levels)
UL 508C, RoHS, IEC 61800-5-1, IEC/EN61000-3-12 THDI harmonic standard
UL File E116875, CSA 2278406, UL 508C, Plenum rated per UL508C for UL1995 installations,
C-Tick, NOM 117, CE marked

Related parts for ATV212WU55N4