MAX1243BCSA Maxim Integrated Products, MAX1243BCSA Datasheet - Page 24

no-image

MAX1243BCSA

Manufacturer Part Number
MAX1243BCSA
Description
ADC (A/D Converters) Integrated Circuits (ICs)
Manufacturer
Maxim Integrated Products
Datasheet

Specifications of MAX1243BCSA

Number Of Adc Inputs
1
Architecture
SAR
Conversion Rate
73 KSPs
Resolution
10 bit
Input Type
Voltage
Interface Type
3-Wire (SPI, QSPI, Microwire)
Voltage Reference
External
Supply Voltage (max)
5.25 V
Supply Voltage (min)
2.7 V
Maximum Power Dissipation
471 mW
Maximum Operating Temperature
+ 70 C
Mounting Style
SMD/SMT
Package / Case
SO-8
Minimum Operating Temperature
0 C
Lead Free Status / Rohs Status
No

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
MAX1243BCSA
Manufacturer:
MAXIM/美信
Quantity:
20 000
Part Number:
MAX1243BCSA+
Manufacturer:
Maxim
Quantity:
100
Part Number:
MAX1243BCSA+T
Manufacturer:
MAXIM
Quantity:
7 647
12-Bit, Multichannel ADCs/DACs with FIFO,
Temperature Sensing, and GPIO Ports
Channels 8–11 are invalid. Any scans or averages on
these channles can cause corrupt data.
Select scan mode 00 or 01 to return one result per sin-
gle-ended channel and one result per differential pair
within the selected scanning range (set by bits 2 and 1,
SCAN1 and SCAN0), plus one temperature result if
selected. Select scan mode 10 to scan a single input
channel numerous times, depending on NSCAN1 and
NSCAN0 in the ADC averaging register (Table 9).
Select scan mode 11 to return only one result from a
single channel.
Issue a command byte to the setup register to config-
ure the clock, reference, power-down modes, and ADC
single-ended/differential modes. Table 5 details the bits
in the setup-register command byte. Bits 5 and 4
(CKSEL1 and CKSEL0) control the clock mode, acqui-
sition and sampling, and the conversion start. Bits 3
and 2 (REFSEL1 and REFSEL0) set the device for either
internal or external reference. Bits 1 and 0 (DIFFSEL1
and DIFFSEL0) address the ADC unipolar-mode and
bipolar-mode registers and configure the analog input
channels for differential operation.
The ADC reference is always on if any of the following
conditions are true:
1) The FBGON bit is set to one in the reset register.
2) At least one DAC output is powered up and
3) At least one DAC is powered down through the
If any of the above conditions exist, the ADC reference is
always on, but there is a 188 clock-cycle delay before
temperature-sensor measurements begin, if requested.
24
REFSEL[1:0] (in the setup register) = 00.
100kΩ to V
______________________________________________________________________________________
REF
and REFSEL[1:0] = 00.
Setup Register
Table 4. Conversion Register*
* See below for bit details.
SCAN1
CHSEL3
CHSEL3
CHSEL2
CHSEL1
CHSEL0
SCAN1
SCAN0
NAME
TEMP
BIT
0
0
1
1
0
0
0
0
0
0
0
0
1
1
1
1
SCAN0
CHSEL2
7 (MSB)
0 (LSB)
0
1
0
1
BIT
6
5
4
3
2
1
0
0
0
0
1
1
1
1
0
0
0
0
Scans channels 0 through N.
Scans channels N through the highest
numbered channel.
S cans channel N r epeated l y. The AD C
aver ag ing reg i ster sets the numb er of
r esul ts.
N o scan. C onver ts channel N once onl y.
Set to one to select conversion register.
Analog input channel select
(MAX1223). Set to 0 on the
MAX1221/MAX1343.
Analog input channel select.
Analog input channel select.
Analog input channel select.
Scan mode select.
Scan mode select.
Set to one to take a single temperature
measurement. The first conversion
result of a scan contains temperature
information.
CHSEL1
(CHANNEL N IS SELECTED BY
0
0
1
1
0
0
1
1
0
0
1
1
BITS CHSEL3–CHSEL0)
CHSEL0
SCAN MODE
FUNCTION
0
1
0
1
0
1
0
1
0
1
0
1
CHANNEL (N)
SELECTED
AIN10
AIN11
AIN0
AIN1
AIN2
AIN3
AIN4
AIN5
AIN6
AIN7
AIN8
AIN9