ARD52012Q Panasonic Electric Works, ARD52012Q Datasheet

ARD52012Q

Manufacturer Part Number
ARD52012Q
Description
Manufacturer
Panasonic Electric Works
Datasheet

Specifications of ARD52012Q

Insertion Loss (max)
0.8dB
Lead Free Status / Rohs Status
Compliant

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
ARD52012Q
Manufacturer:
Panasonic
Quantity:
12 000
ds_61309_en_rd: 010709J
HIGH FREQUENCY CHARACTERISTICS (Impedance 50)
Notes:
ORDERING INFORMATION
RD coaxial switches
Frequency
1: to 18GHz (SPDT)
2: to 18GHz (Transfer)
3: to 13GHz (SP6T)
Operating function
00: Fail-safe (with indicator)
20: Latching (with indicator)
51: Latching with TTL driver (SPDT, Transfer)
Nominal operating voltage, V DC
4H:
05:
Operation terminal
Nil:
C:
Termination (SP6T type only)
Nil:
Z:
HF data attached
Nil:
Q:
Note: Sealed types also available, please consult us (SPDT only)
V.S.W.R. (SP6T With termination) (max.)
*1The 6GHz type only has the above characteristics up to 6GHz.
*218 to 26.5GHz characteristics can be applied 26.5GHz type only (SPDT, Transfer)
(with self cut-off function) (with indicator)
Solder terminal
Connector cable (SPDT type only)
No termination
With termination
No HF test data attached
HF test data attached
4.5 (Fail-safe, Latching type only)
5 (Latching with TTL driver type only)
Insertion loss (dB. max.)
Isolation (dB. min.)
V.S.W.R. (max.)
Frequency
5: to 26.5GHz (SPDT)
6: to 26.5GHz (Transfer)
7: to 6GHz (SPDT)
6GHz type
to 1 GHz
1.1
85
02: Fail-safe (without indicator)
22: Latching (without indicator)
53: Latching with TTL driver (SPDT)
12: 12
24: 24
FEATURES
1. Excellent high frequency
characteristics (50, to 26.5Ghz)
2. SPDT, Transfer and SP6T types are
available.
3. High sensitivity
Nominal operating power:
840 mW (SPDT/SP6T, Fail-safe type,
with indicator)
1,540 mW (Transfer, Fail-safe type, with
indicator)
*Without 24V type
4. Long-lasting life: min. 5  10
5. With termination type is added.
(SP6T)
Thanks to the addition of termination,
steady high frequency characteristics can
be maintained when contacts are either
open or closed and this contributes to
increase system reliability.
6. + COM type is available.
for Communications Market
(with self cut-off function) (without indicator)
RD Coaxial Switch (SPDT)
1.20
0.2
6GHz High Reliability
1 to 4 GHz
1.15
80
Addition of
ARD
4 to 8 GHz*
1.25
1.40
0.3
70
6
1
8 to 12.4 GHz
1.35
1.50
0.4
65
TYPICAL APPLICATIONS
Wireless and mobile communication
• Cellular phone base station
• Amplifier switching
Digital broadcasting
• Broadcasting relay station
• Broadcasting equipment
Measuring instrument
All types of inspection equipment
Please inquire beforehand if you are
thinking of using this product in
applications that involve low level load or
high frequency of switching.
SWITCHES (ARD)
RD COAXIAL
12.4 to 18 GHz
1.5
0.5
60
RD (ARD)
18 to 26.5 GHz*
1.7
0.8
55
2
1

Related parts for ARD52012Q

ARD52012Q Summary of contents

Page 1

HIGH FREQUENCY CHARACTERISTICS (Impedance 50) Frequency V.S.W.R. (max.) V.S.W.R. (SP6T With termination) (max.) Insertion loss (dB. max.) Isolation (dB. min.) Notes: *1The 6GHz type only has the above characteristics up to 6GHz. *218 to 26.5GHz characteristics can be ...

Page 2

... ARD60012Q ARD60024 ARD60024Q ARD6204H ARD6204HQ ARD62012 ARD62012Q ARD62024 ARD62024Q ARD65105 ARD65105Q ARD65112 ARD65112Q ARD65124 ARD65124Q 13GHz type HF datasheet attached ARD3004HQ ARD30012Q ARD30024Q ARD3204HQ ARD32012Q ARD32024Q ds_61309_en_rd: 010709J HF datasheet attached ARD5004HQ ARD50012Q ARD50024Q ARD5204HQ ARD52012Q ARD52024Q ARD55105Q ARD55112Q ARD55124Q — — — ...

Page 3

SP6T (with termination) Nominal operating Operating function voltage 4.5 Fail-safe 12 24 4.5 Latching 12 24 Note: Standard packing; Carton: 1 pc. Case: 5 pcs. RATING 1. Coil data (1) SPDT 1) Fail-safe type Nominal operating current, ...

Page 4

RD (ARD) • Operating voltage range 1) Fail-safe type Nominal voltage Allowable range 2. for use Recommended ...

Page 5

Specifications 1) SPDT/Transfer Characteristics Item Arrangement Contact Contact material Initial contact resistance Contact input power Rating Fail-safe Nominal operating Latching power Contact rating Indicator rating (with Initial contact resistance indicator type only) Min. switching capacity (Reference value) High frequency ...

Page 6

RD (ARD) 2) SP6T Characteristics Item Arrangement Contact Contact material Initial contact resistance No termination Contact input power With termination Rating Nominal Fail-safe operating Latching power Contact rating Initial contact resistance Indicator rating Min. switching capacity (Reference value) No termination ...

Page 7

REFERENCE DATA 1-(1). High frequency characteristics (SPDT) 6GHz type Sample: ARD70012 Measuring method: Measured with Agilent Technologies network analyzer (E8363B). • V.S.W.R. 1.9 1.8 1.7 1.6 1.5 1.4 Standard value 1.3 Reference value 1.2 1.1 1.0 30MHz 1GHz 4GHz 6GHz ...

Page 8

RD (ARD) 1-(4). High frequency characteristics (SP6T) Sample: ARD30012 Measuring method: Measured with Agilent Technologies network analyzer (HP8510). • V.S.W.R. 2.0 1.9 1.8 1.7 1.6 1.5 Standard value 1.4 1.3 Reference value 1.2 1.1 1.0 1GHz 4GHz 8GHz 13GHz 18GHz ...

Page 9

... Indicator Coil GND + Serial No.  + COM type is available * The type without indicator terminals will not have the indicator terminals that are marked with the dotted box. ds_61309_en_rd: 010709J your local Panasonic Electric Works representative. 11.2 .441 3.5 .138 3.5 4.3 .138 ...

Page 10

RD (ARD) 2) Connector cable Fail-safe NC COM NO Indicator terminal Coil terminal GND  + COM type is available 10 Pin No. 1 Fail-safe – Latching – Latching with – TTL driver D-sub connector pin contact type 1 2345 ...

Page 11

Transfer CAD Data Fail-safe Coil terminal Indicator terminal GND  + COM type is available ds_61309_en_rd: 010709J 45.70 1.799 15.24 .600 0.30 .012 3-3.80 dia. 3-.150 dia. Indicator Coil NC GND + COM NO 20.3 .799 Serial No. J1 ...

Page 12

RD (ARD) 3. SP6T CAD Data Fail-safe type Coil terminal GND Indicator terminal COM COM COM Indicator terminal Coil terminal GND ...

Page 13

SP6T (with termination) CAD Data Fail-safe type Coil terminal GND Indicator terminal COM COM COM Indicator terminal Coil terminal GND ...

Page 14

RD (ARD) NOTES 1. For general cautions for use, please refer to the “General Application Guidelines”. 2. Coil operating power Pure DC current should be applied to the coil. The wave form should be rectangular includes ripple, the ...