G6H-2F-5VDC Omron, G6H-2F-5VDC Datasheet - Page 8

no-image

G6H-2F-5VDC

Manufacturer Part Number
G6H-2F-5VDC
Description
Manufacturer
Omron
Type
Signal Relayr
Datasheet

Specifications of G6H-2F-5VDC

Relay Construction
Non-Latching
Contact Arrangement
DPDT
Coil Voltage Dc
5V
Coil Current
28.1mA
Contact Form
2 Form C
Voltage Rating (vdc)
110V
Voltage Rating (vac)
125V
Dropout Volt (min)
0.5VDCV
Coil Resistance
178Ohm
Pick-up Voltage (max)
3.75VDC
Maximum Power Rating
33W/62.5VA
Operate Time
3ms
Contact Current Rating
1A
Coil Suppression Diode
No
Push To Test Button
No
Led Indicator
No
Seal
Sealed
Product Height (mm)
6.6mm
Product Depth (mm)
11.5mm
Product Length (mm)
14.3mm
Operating Temp Range
-40C to 70C
Pin Count
10
Mounting Style
Surface Mount
Termination Style
Gull Wing
Lead Free Status / Rohs Status
Compliant

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
G6H-2F-5VDC
Manufacturer:
VLSI
Quantity:
6 234
Precautions
Long-term Continuously ON Contacts
Using the Relay in a circuit where the Relay will be ON continuously
for long periods (without switching) can lead to unstable contacts
because the heat generated by the coil itself will affect the insulation,
causing a film to develop on the contact surfaces. We recommend
using a latching relay (magnetic-holding relay) in this kind of circuit. If
a single-side stable model must be used in this kind of circuit, we rec-
ommend using a fail-safe circuit design that provides protection
against contact failure or coil burnout.
Claw Securing Force During Automatic Mounting
During automatic insertion of Relays, be sure to set the securing
force of each claw to the following so that the Relay’s characteristics
will be maintained.
56
Direction A: 1.96 N max.
Direction B: 4.90 N max.
Direction C: 1.96 N max.
A
C
B
Low Signal Relay
G6H
DISCONTINUED
Relay Handling
Use the Relay as soon as possible after opening the moisture-proof
package. If the Relay is left for a long time after opening the mois-
ture-proof package, the appearance may deteriorate and seal failure
may occur after the solder mounting process. To store the Relay after
opening the moisture-proof package, place it into the original pack-
age and seal the package with adhesive tape.
When washing the product after soldering the Relay to a PCB, use a
water-based solvent or alcohol-based solvent, and keep the solvent
temperature to less than 40°C. Do not put the Relay in a cold clean-
ing bath immediately after soldering.

Related parts for G6H-2F-5VDC