Specifications of AM29DL640H-90EI

Cell Type
NOR
Density
64Mb
Access Time (max)
90ns
Interface Type
Parallel
Boot Type
Bottom/Top
Address Bus
23/22Bit
Operating Supply Voltage (typ)
3/3.3V
Operating Temp Range
-40C to 85C
Package Type
TSOP
Program/erase Volt (typ)
3/8.5 to 9.5V
Sync/async
Asynchronous
Operating Temperature Classification
Industrial
Operating Supply Voltage (min)
2.7V
Operating Supply Voltage (max)
3.6V
Word Size
8/16Bit
Number Of Words
8M/4M
Supply Current
16mA
Mounting
Surface Mount
Pin Count
48
Lead Free Status / Rohs Status
Not Compliant

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
AM29DL640H-90EI
Manufacturer:
AMD
Quantity:
61
Company:
Part Number:
AM29DL640H-90EI
Quantity:
423
Legend:
X = Don’t care
RA = Address of the memory location to be read.
RD = Data read from location RA during read operation.
PA = Address of the memory location to be programmed. Addresses
latch on the falling edge of the WE# or CE# pulse, whichever happens
later.
Notes:
1.
2. All values are in hexadecimal.
3. Except for the read cycle and the fourth, fifth, and sixth cycle of
4. Data bits DQ15–DQ8 are don’t care in command sequences,
5. Unless otherwise noted, address bits A21–A11 are don’t cares for
6. No unlock or command cycles required when bank is reading
7. The Reset command is required to return to the read mode (or to
8. The fourth cycle of the autoselect command sequence is a read
June 7, 2005
Read (Note 6)
Reset (Note 7)
Enter Secured Silicon
Sector Region
Exit Secured Silicon Sector
Region
Program
Unlock Bypass
Unlock Bypass Program (Note 12)
Unlock Bypass Reset (Note 13)
Chip Erase
Sector Erase
Erase Suspend (Note 14)
Erase Resume (Note 15)
CFI Query (Note 16)
See Table 1 for description of bus operations.
the autoselect command sequence, all bus cycles are write
cycles.
except for RD and PD.
unlock and command cycles, unless SA or PA is required.
array data.
the erase-suspend-read mode if previously in Erase Suspend)
when a bank is in the autoselect mode, or if DQ5 goes high (while
the bank is providing status information).
cycle. The system must provide the bank address to obtain the
manufacturer ID, device ID, or Secured Silicon Sector factory
protect information. Data bits DQ15–DQ8 are don’t care. While
reading the autoselect addresses, the bank address must be the
same until a reset command is given. See the Autoselect
Command Sequence section for more information.
Manufacturer ID
Device ID (Note 9)
Secured Silicon Sector
Factory Protect (Note
10)
Sector/Sector Block
Protect Verify
(Note 11)
Command
Sequence
(Note 1)
Word
Word
Word
Word
Word
Word
Word
Word
Word
Word
Word
Byte
Byte
Byte
Byte
Byte
Byte
Byte
Byte
Byte
Byte
Byte
1
1
4
6
4
4
3
4
4
3
2
2
6
6
1
1
1
Table 12. Am29DL640H Command Definitions
Addr
XXX
AAA
AAA
AAA
AAA
AAA
AAA
AAA
AAA
XXX
XXX
AAA
AAA
555
555
555
555
555
555
555
555
555
555
RA
BA
BA
AA
55
First
Data
RD
AA
AA
AA
AA
AA
AA
AA
AA
AA
AA
F0
A0
B0
90
30
98
Addr
2AA
2AA
2AA
2AA
2AA
2AA
2AA
2AA
XXX
2AA
2AA
555
555
555
555
555
555
555
555
555
555
PA
Second
Am29DL640H
Data
PD
55
55
55
55
55
55
55
55
00
55
55
(BA)AAA
(BA)AAA
(BA)AAA
(BA)AAA
(BA)555
(BA)555
(BA)555
(BA)555
Addr
AAA
AAA
AAA
AAA
AAA
AAA
555
555
555
555
555
555
PD = Data to be programmed at location PA. Data latches on the rising
edge of WE# or CE# pulse, whichever happens first.
SA = Address of the sector to be verified (in autoselect mode) or
erased. Address bits A21–A12 uniquely select any sector. Refer to
Table 2 for information on sector addresses.
BA = Address of the bank that is being switched to autoselect mode, is
in bypass mode, or is being erased. A21–A19 uniquely select a bank.
9. The device ID must be read across the fourth, fifth, and sixth
10. The data is 81h for factory locked, 40h for customer locked, and
11. The data is 00h for an unprotected sector/sector block and 01h for
12. The Unlock Bypass command is required prior to the Unlock
13. The Unlock Bypass Reset command is required to return to the
14. The system may read and program in non-erasing sectors, or
15. The Erase Resume command is valid only during the Erase
16. Command is valid when device is ready to read array data or when
Third
cycles.
01h for not factory/customer locked.
a protected sector/sector block.
Bypass Program command.
read mode when the bank is in the unlock bypass mode.
enter the autoselect mode, when in the Erase Suspend mode.
The Erase Suspend command is valid only during a sector erase
operation, and requires the bank address.
Suspend mode, and requires the bank address.
device is in autoselect mode.
Bus Cycles (Notes 2–5)
Data
A0
90
90
90
90
88
90
20
80
80
(BA)X00
(BA)X01
(BA)X03
(SA)X02
(BA)X02
(BA)X06
(SA)X04
Addr
XXX
AAA
AAA
555
555
PA
Fourth
81/01
00/01
Data
PD
7E
AA
AA
01
00
(BA)X0E
(BA)X1C
Addr
2AA
2AA
555
555
Fifth
Data
02
55
55
(BA)X0F
(BA)X1E
Addr
AAA
555
SA
Sixth
Data
01
10
30
27